SCB9-30-2500-10 Epoxy resin dry-type power transformer

Loading Port:Shanghai

Payment Terms:TT OR LC

Min Order Qty:-

Supply Capability:1000sets set/month

Product Description:

Production introduction

The dry-type transformers are casted with epoxyresin,which are made of high quality materials by means of a strict process with advanced production and testing devices.The product features high reliability and long service life.In accordance with different operation environment,it can be equipped with different protection casings or without casing.It can replace the oil-immersed transformer and be used in the high buildings,business centers,airports,tunnels,chemical plants,nuclear power stations and watercrafts ect.

Normal service conditions
1)Altitude should not be over 1000m:indoor type
2)Highest ambient temperature should not over:+40oC;Highest daily average should not over temperature:+30oC
3)Highest annual average temperature should not over +20oC,lowest temperature should not below -5oC.We can provide transformer operated in special conditions according to user's requirement.

Model designation

Applicable standards
GB6450-1986 Dry-type power transformer
GB4208-1993 Casing protection grade(IP code)
GB/T10228-1997 Technical parameters and requirements for dry-type power transformer
Performance characteristics

1.The product is safe,fire-proof,pollution free,and can be used in the load center directly.
2.High mechanical strength,strong shour-circuit proof capacity,small partial discharge,excellent thermal stability,high reliability,and long service life.
3.Low loss,low noise,energy saving and maintenance free.
4.Excellent heat dissipation,great overload capacity and a large operating capacity is available when ONAF is applied.
5.Good humidity resistance,it's suitable for operating in the highly humid and harsh environment.
6.An intelligent signal and temperature control system is adopted,which can automatically monitor and display all working temperature of the three-phase windings.The blowing fan can give an alarm,switch on and off automatically and conduct tripping operation to protect the transformer.
7.Dur to the structure is compact and weight is light,it can save space and decrease the cost of installation.

Notes for placing orders

Transformer type:rated capacity kVA
Number of phases:three-phase single-phase
High voltage: KV/Low voltage:KV
Frequency:50HZ 60HZ
Tapping range:±4×2.5% ±3×2.5% other
Connection group:Yyn0 Dyn11 other
Impedance voltage:4% 6% other
Cooling method: ONAN ONAF
Protecting grade of outer casing:IP00 IP20 IP30 other

Method of incoming and outgoing line:
1.Incoming line to lower part and outgoing line from upper part
2.Incoming line to upper part and outgoing line form upper part
3.Incoming line to upper part and outgoing line form side part