Loading Port:China main port
Payment Terms:TT or LC
Min Order Qty:-
Supply Capability:-
Features:
·12V/24V automatic identify or user-defined working voltage.
·Gel, Sealed, Flooded and user-defined battery type option.
·With functions of current power calculation, it is convenient to view charging and discharging energy of each day, month, year and total value.
·Wide input voltage range:DC8.0V—DC32V, compatible with 12V/24V full voltage range.
·Digital precision constant current control and the control accuracy are better than ± 2%.
·Maximum output efficiency of 95%.
·The rated output current can be adjusted at rated power and current range.
·The max output voltage can reach up to 60V
·Charge control parameter, the load control parameter and the output current value can
be set separately.
·Use of standard Modbus communication protocol for TTL232 bus connections,
communication protocol compatibility much better.
·Fully encapsulated PCB, IP67 protection.
·Aluminum housing.
Load control mode:
Manual, Light ON/OFF, Light ON+ Timer, Time Control
Electronic Protections:
·PV array short circuit
·PV reverse polarity
·High voltage transients
·Over discharge
·Overcharge
·Load overload
·Load short circuit
·Battery reverse polarity
·Overheating
Specification:
Electrical parameters | LS102460BPL | LS152480BPL | LS2024100BPL |
Nominal system voltage | 12 / 24VDC | ||
Battery terminal voltage | 8~32V | ||
Maximum PV input voltage | 50V | ||
Rated charge current | 10A | 15A | 20A |
Rated output power | 30W/12V, 60W/24V | 40W/12V, 80W/24V | 50W/12V, 100W/24V |
Rated output current | 2.0A | 2.6A | 3.3A |
Max. efficiency | 95% | ||
Output voltage range | Voltage of battery~60.0V | ||
Load open circle voltage | 60.0V | ||
Power output adjustment time | <10s | ||
Self-consumption | ≤9.1mA(12V); ≤7.0mA(24V) | ||
Control accuracy | < 2% | ||
Temp. compensation coefficient | -3mV/℃/2V(25℃) | ||
Enclosure | IP67 | ||
Dimension | 108.5x73x25.6 mm | 108.5x96x25.6mm | 108.5x110x25.6mm |
Power cable | 4mm2(PV/Batt.) 1.0mm2(Load) | 6mm2(PV/Batt.) 1.5mm2(Load) | 6mm2(PV/Batt.) 1.5mm2(Load) |
Net weight | 0.4kg | 0.5kg | 0.6kg |
Working temperature | -35℃ to +55℃ | ||
Humidity | ≤90%(NC) |
FAQ
Q1. What is the difference between MPPT&PWM?
A1. MPPT has higher efficiency, it can track the max power point and won't waste energy.
Q2. What is the efficiency of the MPPT controller?
A2. MPPT>99%, peak conversion efficiency>98%.
Q3. What is the waranty of product?
A3. 12 months.
Q4. What protection does your MPPT controller have?
A4. PV array short circuit, PV reverse polarity, Battery reverse polarity, Over charging, Output short circuit.