Loading Port:Shanghai
Payment Terms:TT OR LC
Min Order Qty:-
Supply Capability:1000000meters m/month
XLPE house wiring electrical cable
Features and Applications
XLPE insulated control cable is available for control,inspect loop and protection or other fixed installation of rated voltage 450/750V and below GB/T9330.3-2008
Executive Standard
XLPE insulation PVC sheathed control cable: according to GB/T9330.3-2008
Flame retardant 105°C,135°C control cable burning test according to GB/T12666-2008
Operation Performance
1. Rated AC voltage: U0/U 450/750V
2. Long-term allowed working temperature of cable conductor: 90°C
3. Min. installation temperature: no less than 0°C
4. Cable min. bending radius: 8 times of cable nutter diameter with non-armored cable 12 times of cable nutter diameter with armored or Cu screening cable
Basic Types
table 1
Type | Designation |
KYJV | XLPE insulated PVC sheathed control cable |
KYJVP | XLPE insulated PVC sheathed woven screening control cable |
KYJVP2 | XLPE insulated PVC sheathed Cu tape screening control cable |
KYJVP3 | XLPE insulated PVC sheathed AL-plastic tape screening control cable |
KYJV22 | XLPE insulated PVC sheathed steel tape armored control cable |
KYJVP2-22 | XLPE insulated PVC sheathed Cu tape screening steel tape armored control cable |
KYJV32 | XLPE insulated PVC sheathed steel wire armored control cable |
KYTY | XLPE insulated PO sheathed control cable |
KYJYP | XLPE insulated PO sheathed woven screening control cable |
KYJYP2 | XLPE insulated PO sheathed Cu tape screening control cable |
KYJYP3 | XLPE insulated PO sheathed Al- plastic tape screening control cable |
KYJY23 | XLPE insulated PO sheathed steel tape armored control cable |
KYJYP2-23 | XLPE insulated PO sheathed Cu tape screening steel tape armored control cable |
KYJY33 | XLPE insulated PO sheathed steel wire armored control cable |
Note:Cable models not listed in upper table could combined according to 4th chapter of GB/T19330.1-2008. |
Product structure
Cable structure according to table 2
Type | mm2 Conductor nominal sector | |||||||
0.75 | 1.0 | 1.5 | 2.5 | 4 | 6 | 10 | ||
No. Core | ||||||||
KYJV KYJVP KYJY KYJYP | 2-61 | 2-14 | 2-10 | |||||
KYJVP2 KYJVP3 KYJYP2 KYJYP3 | 4-61 | 4-14 | 4-10 | |||||
KYJV-22 KYJY-23 | 7-61 | 4-61 | 4-14 | 4-10 | ||||
KYJVP2-22 KYJYP2-23 | 7-61 | 4-61 | 4-14 | 4-10 | ||||
KYJV32 KYJY33 | 19~61 | 7~61 | 4~14 | 4~10 | ||||
Note: Non-listed cable structure in upper table should added according to customers' request. | ||||||||
Type Explanation
1.Code, designation and definition
Item | Code | Definition |
Flame-retardant character | / ZR ZR-135 | Non flame-retardant can be omitted Flame-retardant to 105°C Flame-retardant to 135°C |
Series code | K | Control cable |
Insulation material | V YJ VD | PVC XLPE Low-smoke & halogen PVC |
Sheath material | V VD | PVC Low-smoke & halogen PVC |
Shield material | P P2 P3 | Cu wire of Tin-plated woven Cu wire Cu tape or Cu plastic compound tape Al/plastic compound tape |
Armor material | 22 32 | Steel tape Steel-gauge steel-wire |
Conductor type | A B R | Single-strand conductor 7-strands twisted conductor Muti-strands twisted conductor |
Specification Size
1. KVV, KYJV, KVVP, KYJVP, KVV22, KYJV22, ZR-KVV, ZR-KYJV, ZR-KVVP, ZR-KYJVP,
ZR-KVVP2, ZR-KYJVP2, ZR-KVV22(105°C,135°C)
Note: The outer diameter of armored cable could add 4.0mm
Marking Examples:
Example 1:Cu conductor XLPE insulated&sheathed, woven Cu wire shield control cable. 19 core 1.5mmz. the core conductor is formed of single wire, to be described as: KYJVP 19 X 1.5;
Example 2: Cu conductor flame-retardant 105°C PVC sheathed&insulated steel tape armor control cable, 20 core 1.0mm2, the core conductor is formed of mufti-stands twisted Cu wire, to be described as: ZR105-KVV22,R 20 X 1.0;
Example 3: Cu conductor flame-retardant 135°C PVC sheathed&insulated, Cu tape shield control cable, 24 core 1.5mm2, the conductor is formed of single wires, to be described as: ZR135-KVVP2 24 x 1.5;