Application
These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and out doors, in cable ducts, underground, in power and swiching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.
Contruction
Conductors: Copper or aluminum conductor, round stranded or shaped, Class 2 to IEC 60228, BS EN 60228. For smaller sizes, a solid round conductor, Class 1 as per IEC 60228, BS EN 60228 can also be supplied upon request.
Insulation: XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90℃ continuous operation.
Colour Code: As per standard.
Assembly/Inner sheath: Two, three or four insulated conductor are laid-up together with non-hygroscopic fillers and the assembly is bedded with an extruded layer of PVC. In case of non-armoured cables, this layer may be ommited.
Armour: Aluminum/Galvanized ateel wires applied helically over the bedding as per IEC 60502 or as per BS 5467, BS 6346. Single core cables shall be aluminum wire armour, aluminum/ steel tapes applied helicaly over the bedding of multi-core cables as per IEC 60502.
Outter Sheath: Outter sheath shall be of extruded PVC type ST2 as per IEC 60502-1 or type 9 as BS 6346/5467.
Special type of PVC sheathing material such as fire retardant PVC, anti-termit PVC, anti-rodent PVC, sunshine resistant PVC, oil resistant PVC are available on special request. Also, special sheathing material such as LLDPE, MDPE, HDPE, LSF, CPE are available on request.
Fire Performance of Cable Sheath: Cables can be supplied with special flame retardant PVC outter sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, can also supply cables with Low Smoke Halogen Free(LSHF) material according to IEC 60502-1, BS 7211, BS 6724 or other quivalent standards.
Nominal Cross-sectional Areas
1.5 mm2 , 2.5 mm2 ,4 mm2 , 6 mm2 , 10 mm2 , 16 mm2 , 25 mm2 , 35 mm2 , 50 mm2 ,70 mm2 ,
95 mm2 , 120 mm2 , 150 mm2 ,185 mm2 , 240 mm2 , 300 mm2 , 400 mm2 , 500 mm2 , 630 mm2
3 core electric cable 95mm2 power cable
Scope of Power Cable
sta swa armoured 33kv single core power cable
Type | Description | Application | |
Cu | Al | ||
Cu/PVC/PVC Cu/XLPE/PVC | Al/PVC/PVC Al/XLPE/PVC | PVC or XLPE insulation PVC sheath power cable | To be laid indoors, in tunnel, cable furrow or pipe, the cable couldn't bear mechanical force outside |
Cu/PVC/PE Cu/XLPE/PE | Al/PVC/PE Al/XLPE/PE | PVC or XLPE insulation PE sheath power cable | |
Cu/PVC/STA/PVC Cu/XLPE/STA/PVC | Al/PVC/STA/PVC Al/XLPE/STA/PVC | PVC or XLPE insulation, steel tape armor, PVC sheath power cable | To be laid underground, the cable could bear certain mechanical force, but it couldn't bear great pulling force. |
Cu/PVC/STA/PE Cu/XLPE/STA/PE | Al/PVC/SWA/PE Al/XLPE/SWA/PE
| PVC or XLPE insulation, steel tape armor, PE sheath power cable | |
Cu/PVC/ATA/PVC Cu/XLPE/ATA/PVC | Al/PVC/ATA/PVC Al/XLPE/ATA/PVC | PVC or XLPE insulation, have no the magnetism steel tape armor, PVC sheath power cable | |
Cu/PVC/(thin)SWA/PVC Cu/XLPE/ (thin)SWA/PVC | Al/PVC/(thin) SWA/PVC Al/XLPE/(thin) SWA/PVC | PVC or XLPE insulation, thin steel-wire armor, PVC sheath power cable | Be applicable to the well, water inside and fall in the bad soil, the cable cans bear the equal dint outside the machine with pull the dint . |
Cu/PVC/AWA/PVC Cu/XLPE/AWA/PVC | Al/PVC/AWA/PVC Al/XLPE/AWA/PVC | PVC or XLPE insulation, have no the magnetism thick steel-wire armor, PVC sheath power cable | |
Cu/PVC/(thick)SWA/PVC Cu/XLPE/(thick) SWA/PVC | Al/PVC/ (thick)SWA/PVC Al/XLPE/ (thick)SWA/PVC | PVC or XLPE insulation, thick steel-wire armor, PVC sheath power cable | Be applicable to the well, underwater with the bottom of sea, the cable cans bear the bigger pressure with lead to pull the dint. |
/Voltage Test
Each drum of finished cable should withstand power frequency voltage 3.5kV for 5 minutes, the insulation is not breakdown.
Service conditions and parameters of cable
The cable is applied to fixed installation for rated voltage 0.6/1kV of power transportation and distribution line.
Max. rated temperature of conductor. nominal operating 70℃.
Short circuit:max. for 5 sec.160℃
The cable can be laid without drop retriction, and the environment temperature shall not be lower than 0℃.