Loading Port:China main port
Payment Terms:TT OR LC
Min Order Qty:1000 m
Supply Capability:20000 m/month
Applied for installation of motor, electric appliance and meter circuit of AC
rated voltage 500V. working temp -60c --180c
HIGH QUALITY
LOW PRICE
Model and name
Model | Name |
TL-AGR | SILICONE RUBBER INSULATED INSTALLATION WIRE |
TL-AGR | SILICONE RUBBER INSULATED HEAT-RESISTANCE INSTALLATION WIRE OF MOTOR AN ELECTRIC APPLIANCE |
TL-AGRP | SILICONE RUBBER INSULATED AND SHIELED INSTALLATION WIRE |
Main technical reuirements
1. As specified in the table, the wire can bear the spark test of AC 50hz, dip in water for 6h, or subject to withstand voltage test 1 min, without any breakdown.
2. Heat test: at +200c an 96h, the winding show no crack
3. sealing resistance: at -60 and for 2h, the winding show no flaw.
4. Paint resistance test: +135c, dry for 12-14h first, then ip in the paint of +20c for 30 min, after taking it out to dry up, repeat this operation as per prior test steps, at last, dry it at +135c and for 12-14h and wind, the insulated layer has no crack and brittle failure.