Loading Port:China Main Port
Payment Terms:TT or LC
Min Order Qty:50000 unit
Supply Capability:3000000 unit/month
1. Structure of Solar Photovoltaic Grid-Connected Inverter SG60KTL Description
Suitable for 50Hz/60Hz grid, could be used in Asia, Africa and Europe. Available for hand installation, no need for lifting machinery assistance.
IP65;Integrated DC combine and surge protection function
TUV,CE,G59/3,BDEW,CGC,GB-T19964
2. Main Features of the Solar Photovoltaic Grid-Connected Inverter SG60KTL
Flexible
• Handy and light, easy to handle without lift machinery assistance, lower the cost of installation and maintenance.
• Integrated DC combine and surge protection function, lower the system cost
• DC arc detection function(optional), further enhance the safety performance
Efficient
• Max. Efficiency at 99%
• Integrated string detection function, find mismatch panel in time and accurately
• Integrated PV panel PID effect eliminate function( optional), decrease the loss of generation attenuation.
Grid-friendly
• Fullfil a variety of reactive power adjustment requirments with power factor 0.8overexited ~0.8 underexited
• Active power continuously adjustable (0~100%)
• Integrated LVRT , HVRT and night SVG function
Qualified
• TÜV, CE, G59/3, BDEW, CGC and GB-T19964 certification.
3. Solar Photovoltaic Grid-Connected Inverter SG60KTL Images
4. Solar Photovoltaic Grid-Connected Inverter SG60KTL Specification
Grid Type | 230V/400Vac |
Input Side Data | |
Max. PV input power | 67500W |
Max. PV input voltage | 1000V |
Startup voltage | 620V |
MPP voltage range | 570~950V |
MPP voltage range for nominal power | 570~850V |
No. of MPPTs | 1 |
Max. number of PV strings per MPPT | 12 |
Max. PV input current | 120 |
Max. current for input connector | 12A |
Output Side Data | |
Nominal AC output power | 60000W |
Max AC output power(PF=1) | 66000W |
Max. AC output apparent power | 66000VA |
Max. AC output current | 96A |
Nominal AC voltage | 3P+N+PE/3P+PE, 230/400Vac |
AC voltage range | 310~480Vac |
Nominal grid frequency | 50Hz/60Hz |
Grid frequency range | 45~55Hz/55~ 65Hz |
THD | < 3 % (Nominal power) |
DC current injection | <0.5 %In |
Power factor | >0.99@default value at nominal power,(adj. 0.8overexcited ~0.8underexited) |
Protection | |
Anti-islanding protection | Yes |
LVRT | Yes |
DC reverse connection protection | Yes |
AC short circuit protection | Yes |
Leakage current protection | Yes |
DC switch | Yes |
AC switch | Optional |
DC fuse | Yes |
PV String detection | Optional |
ARC detection | Optional |
DC Overvoltage protection | DC Type II DIN rail surge |
AC Overvoltage protection | Optional AC Type II DIN |
System Data | |
Max. efficiency | 99.00% |
Max. European efficiency | 98.70% |
Isolation method | Transformerless |
Ingress protection rating | IP65 |
Night power consumption | <1W |
Operating ambient temperature range | -25~60℃(>50℃ derating) |
Allowable relative humidity range | 0~100% |
Cooling method | Smart forced air cooling |
Max. operating altitude | 4000m (>3000m derating) |
Display | Graphic LCD |
Communication | RS485 |
DC connection type | MC4/Screw Clamp terminal |
AC connection type | Screw Clamp terminal |
Certification | VDE0126-1-1,EN62109-1,EN62109-2,G59/3, |
Mechanical Data | |
Dimensions(W×H×D) | 634×959×267mm |
Mounting method | Wall bracket |
Weight | 55kg |
*Specifications subject to change without notice.
5. FAQ of Solar Photovoltaic Grid-Connected Inverter SG60KTL
Q1. What is the difference between inverter and solar inverter?
A1. Inverter only has AC inpput, but solar inverter both connect to AC input and solar panel, it saves more power.
Q2. What is the difference between MPPT&PWM?
A2. MPPT has higher efficiency, it can track the max power point and won't waste energy.