1.Single conductor Type UD Cable- Aluminum Conductor
1.1 Applications
Directly buried or installed in ducts for 600 volt secondary distribution.
1.2 Standards
Secondary UD single conductor 600V cable meets or exceeds the following ASTM specifications.
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation".
B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
Secondary UD single conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
"USE-2" per UL 854 available upon request.
1.3 Options
Cable in Duct (CIC)
Abrasion Resistant
Ampacity
90oC conductor temperature, 20oC ambient, RHO factor 90, 100% load factor for three conductor triplexed, 3 phase operation. To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
1.4 Specification
Item | Size AWG or | Stranding | Insulation | Outside Dia. | Weight Per KM |
MCM | mm | mm | Kg | ||
Princeton | 6 | 7/W | 1.524 | 7.57 | 66.96 |
Mercer | 4 | 7/W | 1.524 | 8.76 | 95.23 |
Clemson | 2 | 7/W | 1.524 | 10.24 | 138.38 |
Kenyon | 1 | 19/W | 2.032 | 13.26 | 220.22 |
Harvard | 1/0 | 19/W | 2.032 | 12.24 | 181.54 |
Yale | 2/0 | 19/W | 2.032 | 14.38 | 266.35 |
Tufts | 3/0 | 19/W | 2.032 | 15.65 | 322.90 |
Beloit | 4/0 | 19/W | 2.032 | 17.07 | 394.32 |
Hofstra | 250 | 37/W | 2.413 | 19.00 | 471.70 |
Gonzaga | 300 | 37/W | 2.413 | 20.35 | 552.05 |
Rutgers | 350 | 37/W | 2.413 | 21.62 | 629.42 |
Emory | 500 | 37/W | 2.413 | 24.87 | 861.55 |
Duke | 600 | 61/W | 2.794 | 27.58 | 1043.09 |
Furman | 700 | 61/W | 2.794 | 29.34 | 1196.35 |
Sewanee | 750 | 61/W | 2.794 | 30.18 | 1272.24 |
Fordham | 1000 | 61/W | 2.794 | 33.96 | 1650.19 |
2.Duplex Conductor Type URD Cable-Aluminum Conductor2.1 Applications
Directly buried or installed in ducts for 600 volt secondary distribution.
2.2 Standards
Secondary UD duplex conductor 600V cable meets or exceeds the following ASTM specifications.
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation".
B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
Secondary UD duplex conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
"USE-2" per UL 854 available upon request.
2.3 Options
Cable in Duct
Abrasion Resistant
Ampacity
90oC conductor temperature, 20oC ambient, RHO 90, 100% load factor. All yellow extruded stripe cable is XLP insulation. To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
2.4 Specification
Item | Phase Conductor size | Phase Conductor Stranding | Phase Conductor Insulation Thickness | Neutral Size | Neutral Stranding | Neutral Insulation Thickness | Single Phase Conductor | Single Phase Conductor | Weight Per Km |
AWG | mm | AWG | mm | mm | mm | Kg | |||
Bard | 8 | 7/w | 1.524 | 8 | 7/w | 1.524 | 6.65 | 13.31 | 113.09 |
Claflin | 6 | 7/w | 1.524 | 6 | 7/w | 1.524 | 7.59 | 15.14 | 135.41 |
Delgado | 4 | 7/w | 1.524 | 4 | 7/w | 1.524 | 8.76 | 17.53 | 191.95 |
Everett | 2 | 7/w | 1.524 | 2 | 7/w | 1.524 | 10.24 | 20.47 | 281.23 |
3.Triplex Conductor Type URD Cable- Aluminum Conductor
3.1 Applications
Directly buried or installed inducts for 600 volt secondary distribution.
3.2 Standards
Secondary UD triplex conductor 600V cable meets or exceeds the following ASTM specifications.
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation".
B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
Secondary UD triplex conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
"USE-2" per UL 854 available upon request.
3.3 Options
Cable in Duct (CIC)
Abrasion Resistant
Ampacity
90oC conductor temperature, 20oC ambient, RHO 50, 100% load factor for three conductor triplex with neutral carrying only unbalanced load. Technical data for cable with solid black neutral is identical to yellow extruded stripe data. All yellow extruded stripe cable is XLP insulation. To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
3.4 Specification
Item | Phase Conductor size | Phase Conductor Stranding | Phase Conductor Insulation Thickness | Neutral Size | Neutral Stranding | Neutral Insulation Thickness | Single Phase Conductor | Single Phase Conductor | Weight Per Km |
AWG | mm | AWG | mm | mm | mm | Kg | |||
Erskine | 6 | 7/w | 1.524 | 6 | 7/w | 1.524 | 7.59 | 16.41 | 212.78 |
Vassar | 4 | 7/w | 1.524 | 4 | 7/w | 1.524 | 8.76 | 19.15 | 302.06 |
Stephens | 2 | 7/w | 1.524 | 4 | 7/w | 1.524 | 10.24 | 21.39 | 392.83 |
Ramapo | 2 | 7/w | 1.524 | 2 | 7/w | 1.524 | 10.24 | 22.20 | 437.47 |
Brenau | 1/0 | 19/w | 2.032 | 2 | 7/w | 1.524 | 13.26 | 27.03 | 607.10 |
Bergen | 1/0 | 19/w | 2.032 | 1/0 | 19/w | 2.032 | 13.26 | 28.78 | 691.92 |
Converse | 2/0 | 19/w | 2.032 | 1 | 19/w | 2.032 | 14.38 | 29.82 | 746.98 |
Hunter | 2/0 | 19/w | 2.032 | 2/0 | 19/w | 2.032 | 14.38 | 31.19 | 833.28 |
Hollins | 3/0 | 19/w | 2.032 | 1/0 | 19/w | 2.032 | 15.65 | 32.41 | 901.73 |
Rockland | 3/0 | 19/w | 2.032 | 3/0 | 19/w | 2.032 | 15.65 | 33.93 | 1008.86 |
Sweetbriar | 4/0 | 19/w | 2.032 | 2/0 | 19/w | 2.032 | 17.07 | 35.28 | 1099.63 |
Monmouth | 4/0 | 19/w | 2.032 | 4/0 | 19/w | 2.032 | 17.07 | 37.01 | 1232.06 |
Pratt | 250 | 37/w | 2.413 | 3/0 | 19/w | 2.032 | 19.00 | 39.07 | 1328.78 |
Wesleyan | 350 | 37/w | 2.413 | 4/0 | 19/w | 2.032 | 21.62 | 44.09 | 1735.01 |
Holyoke | 500 | 37/w | 2.413 | 300 | 37/w | 2.413 | 24.87 | 51.00 | 2391.22 |
Rider | 500 | 37/w | 2.413 | 350 | 37/w | 2.413 | 24.87 | 51.69 | 2474.54 |
Fairfield | 750 | 61/w | 2.794 | 500 | 37/w | 2.413 | 30.1752 | 52.98 | 3428.35 |
4.Quadruplex Conductor Type URD Cable & Mobile Home Feeder
4.1 Applications
Directly buried or installed in ducts for 600 volt secondary distribution.
4.2 Standards
Secondary UD quadruplex conductor 600V cable meets or exceeds the following ASTM specifications.
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation".
B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
Secondary UD quadruplex conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
"USE-2" per UL 854 available upon request.
4.3 Options
Cable in Duct (CIC)
Abrasion Resistant
Ampacity
To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
4.4 Specification
Item | Phase Conductor size | Phase Conductor Stranding | Phase Conductor Insulation Thickness | Neutral Size | Neutral Stranding | Neutral Insulation Thickness | Single Phase Conductor | Single Phase Conductor | Weight Per Km |
AWG | mm | AWG | mm | mm | mm | Kg | |||
Tulsa | 4 | 7 | 1.524 | 4 | 4 | 1.524 | 8.76 | 21.16 | 383.90 |
Dyke | 2 | 7 | 1.524 | 4 | 4 | 1.524 | 10.24 | 23.83 | 514.85 |
Wittenberg | 2 | 7 | 1.524 | 2 | 2 | 1.524 | 10.24 | 24.71 | 558.00 |
Notre Dame | 1/0 | 19 | 2.032 | 2 | 2 | 1.524 | 13.26 | 30.18 | 805.01 |
Purdue | 1/0 | 19 | 2.032 | 1/0 | 1/0 | 2.032 | 13.26 | 32.00 | 886.85 |
Syracuse | 2/0 | 19 | 2.032 | 1 | 1 | 2.032 | 14.38 | 33.43 | 988.03 |
Lafayette | 2/0 | 19 | 2.032 | 2/0 | 2/0 | 2.032 | 14.38 | 34.72 | 1071.36 |
Swarthmore | 3/0 | 19 | 2.032 | 1/0 | 1/0 | 2.032 | 15.65 | 36.32 | 1197.84 |
Davidson | 3/0 | 19 | 2.032 | 3/0 | 3/0 | 2.032 | 15.65 | 37.77 | 1300.51 |
Wake Forest | 4/0 | 19 | 2.032 | 2/0 | 2/0 | 2.032 | 17.07 | 39.62 | 1456.75 |
Earlham | 4/0 | 19 | 2.032 | 4/0 | 4/0 | 2.032 | 17.07 | 41.22 | 1586.21 |
Slippery Rock | 350 | 37 | 2.413 | 4/0 | 4/0 | 2.032 | 21.62 | 49.40 | 2297.47 |
Wofford | 500 | 37 | 2.413 | 350 | 350 | 2.413 | 21.62 | 59.64 | 3234.91 |
Windham | 750 | 61 | 2.794 | 500 | 500 | 2.413 | 24.87 | 72.39 | 3782.50 |