Shanghai factory multi-fiber sheath construction control cabinet shielded cable RVVP gb

Loading Port:Shanghai

Payment Terms:TT OR LC

Min Order Qty:300 m

Supply Capability:300 m/month

Product Description:

The product name

Rated voltage: 300 v / 500 v conductor: many strands of copper conductor, accord with GB/T 3956 class 5 (equivalent to IEC60228.5).

Insulation: polyvinyl chloride (PVC) mixture.

Block: tinned copper wire braided shielding, weave density is greater than 85%

Sheath: flexible polyvinyl chloride (PVC) mixture, gray (RAL7001).

Core wires logo: 5 or less core, color core; Black conductor white Numbers, can contain the yellow green line.

Conductor: 2-24 core.

Cross-sectional area: 0.5 - was 25.

Name: RVVP cable, RVVP wires, RVVP cables, RVVP wires, RVVP cables, RVVP wires, RVVP cables, RVVP wires, test voltage: 2000 v, 5 min.

Insulation resistance: > 20 m ohm x KM.

Using temperature (fixed installation) : - 30 ~ + 70 ℃.

Use the temperature (mobile) : - 5 ~ + 70 ℃.

Bending radius: 15 x cable diameter.

Flame retardant properties: IEC 60 332.1.

Reference standard: JB8734, VDE 0281.

Packing specification: 100 m, 500 m and 1000 m.

2 application scope

Compared with RVV RVVP cable cable, with steel wire braided shielding, electromagnetic compatibility characteristics of this product is better. Therefore, especially for the electromagnetic environment is bad, installation from smaller places. RVVP cable products can be installed on the bridge, hose, used for indoor installation.

3 cable specification

Some x standard cross-sectional area

2 x, 3 x, 4 x 0.50 0.50, 0.50 5 * 0.50, 0.50, 6, 7 x 0.50, 8 x 0.50, 10 x 0.50, 18 x 0.50 x 0.50, 12, 24 x 0.50. 2 x, 3 x, 4 x 0.75 0.75, 0.75 5 * 0.75, 0.75, 6, 7 x 0.75, 8 x 0.75, 10 x 0.75, 18 x 0.75 x 0.75, 12, 24 x 0.75. 2 x, 3 x, 4 x 1.0 1.0, 1.0 5 * 1.0, 1.0, 6, 7 x 1.0, 8 x 1.0, 10 x 1.0, 18 x 1.0 x 1.0, 12, 24 x 1.0. 2 x, 3 x, 4 x 1.5 1.5, 1.5 5 * 1.5, 1.5, 6, 7 x 1.5, 8 x 1.5, 10 x 1.5, 18 x 1.5 x 1.5, 12, 24 x 1.5. 2 x, 3 x, 4 x 2.5 2.5, 2.5 5 * 2.5, 2.5, 6, 7 x 2.5, 8 x 2.5, 10 x 2.5, 18 x 2.5 x 2.5, 12, 24 x 2.5. 3 x, 4 x, 5 x 4.0 4.0, 4.0 7 x 4.0. 3 x, 4 x, 5 x 6.0 6.0, 6.0 7 x 6.0. 3 x, 4 x, 5 x 10.0 10.0 10.0. 3 x, 4 x, 5 x 16.0 16.0 16.0. 4 x, 5 x 25.0 25.0.

4 other introduction

Purpose: the equipment, instrumentation, intercom, monitoring, control, installation, audio broadcasting,

5 using range

Is fit for ac rated voltage up to and including 300/300 electric, instrument and electronic equipment and automation devices such as shielding line

Execution standard JB8734.5-1998

Using features rated voltage: 300/300 v

Rated temperature: AVP - 90, RVP - 90-90 ℃, and other characteristics of model 70 ℃

Conductor: many strands of bare wire (or tin plated copper wire) stranded

Shielding method: woven or inclined round (customer requirements)

Some conductors: 1-24 core

Insulation, RVP: (1) the AVP - 90-90: PVC/E PVC insulated (2) the AVP: PVC/C type PVC insulated (3) the rest of the models: PVC/D type PVC insulated

Twisted: insulated conductor cable with filling (if any).