Loading Port:Tianjin
Payment Terms:TT OR LC
Min Order Qty:1000 pc
Supply Capability:30000 pc/month
The RF card water meter (DN15) consists if a valve device, a movement, a sensor, a reducer, a battery, an electorinic module, and a radio frequency card. It has prepaid and cintrilled function.
It implements the CJ/T133 standard. The indication error and measurement width with the GB/T778.1 (equivalent to ISO4064).
The main technical parameters
Pulse constant: 10
Quiescent current: ≤6uA
Dynamic current: implements : ≤20mA
Actuator maximun current : ≤60mA
Working voltage: 2.8V to 3.6V
Q1 to Q2, excluding Q2 indication error ≤±5%, Q2 to Q3 (including Q2) indication error ≤±2%
Features
When the battery is not powered or the battery is replaced, the valve is automatically closed to effectively prevent water theft. When the battery is powered, the valve is automatically opened, which does not affect the user's water.
Anti-attack design, anti-magnetic, anti-vibration. When a magnetic object is close to the water meter, the valve is automatically closed to prevent the magnetic object from interfering with the meter.
Pre-paid function, after the card is recharged, the water is swiped, and the remaining amount or amount is automatically reduced when the water is used. The remaining amount is automatically closed.
For the query funtion, the user can query the remaining amount, water consumption and other related information on the water meter LCD.
One meter to one card, the user first puechases the water card and the water meter is bound, one water meter corresponds to one card is locked.
The card replenishment funtion, the replenishment card continues the data in the original meter and the amount or amount of water remaining
Anti fouling function, automatic opening and closing of the valve at regular intervals, not only prevent ball valve fouling, but also solve the lithium battery voltage hysteresis problem.
Power-down protection function, power off or no power, the microconteoller automatically saves data
Low voltage protection, when the battery voltage is lower than the set valve, the valve is automatically closed.
Flow point verification parameters and installation size parameters
Serial Number | Specification | Maximum flow Q1 | Maximum flow Q3 | Transitional flow Q2 | Minimum flow Q1 | Total length | Width | Height | Connection thread |
1 | DN15 | 3.125m3/h | 2.5m3/h | 0.02m3/h | 0.02m3/h | 165 | 82 | 100 | GB 1/2' |
2 | DN20 | 4m3/h | 4.0m3/h | 0.032m3/h | 0.032m3/h | 195 | 82 | 100 | GB 3/4' |
3 | DN25 | 6.3m3/h | 6.3m3/h | 0.0504m3/h | 0.0504m3/h | 225 | 82 | 100 | GB 1' |