Loading Port:Tianjin
Payment Terms:TT or LC
Min Order Qty:-
Supply Capability:99 units unit/month
Type description
Take 350QZB-50 as an example
350: the nominal diameter of the pump
Q: submersible
Z: axial flow
B: semi-adjustable blade
50: 1/10 of the pump specific speed (take the integer part)
According to different pump specific speeds, the flow capacity range of this type of axial flow pump can reach up to 700m3-1400 m3
The principle of Axial flow pump is to lifting water according to the thrust caused by the impeller when rotating. Because water moves along the axial in the impeller, so we called it axial flow pump.
In accordance with its mode of installation, axial flow pump can be distinguished into three class: vertical, horizontal, inclined. Their structures are almost the same. Now the vertical form is used widely. The main accessories contains bell-mouthed pipe, impeller, guide blade, outlet syphon, shaft and bearing, stuffing box, etc.
Summarize of QZ series Axial flow pump:
Installation of water flow Channel: in terms of recommended sample installation diagram
The form of water exit: flap valve or other ways
Installation ways: suspended by bent pipe; suspended in well casing, etc.
Motor
Submersible motor
Power Level: electrical performance conforms to GB756
Protection level: IP68
Cooling method: ICW08A41
Basic installation form: IM3013
Voltage grade: ≤355kw, voltage,380v/660v; 355kw,voltage, 380v, 660v, 6000v, 10000v
Insulation level: F
Rated frequency: 50Hz
Length of cable: 10m
Shaft seal
There are two or three stages of mechanical seal. The first stage called carborundum (directly contact with water). The second and third stage called graphite and carborundum.
Leak proof Equipment
QZ, QH series pump have been equipped with leak proof sensors. When the oil tank, the inner part of motor or the junction box has been leaked by water, the sensor will signal or made the motor shut down, and retain the malfunction signal.
Over heating protection system
A overheating protection device is fastened on the motor winding. When the temperature exceeds the stated &#118alue, the device will signal or made the motor shut down.
Rotation direction:
Seen from the top of the motor, the impeller is rotating clock wisely.
Application
QZ series axial flow pump, QH series mixed-flow pump is widely used in industry and agriculture water lifting, urban water supply, light polluted water discharge and other water transfer project.
Working condition
Clean water with the temperature no more than 50 or some liquids that are similar to water.