PU Polyurethane Foam Sandwich Panel Frame Panel (CE/SAA)

Loading Port:Tianjin

Payment Terms:TT OR LC

Min Order Qty:1000 m²

Supply Capability:1000000 m²/month

Product Description:

Specifications

1. Variety of Surface Steel 
2. Thickness: 50/75/100/150mm 
3. Fire Resistance: B2 
4. Density: 38~42kgs/m3 
5. Connect:Cam-lock

PU Polyurethane Foam Sandwich Panel Frame Panel 

Combined Cold Storage Library Structure

Combination cold storage was assembled by PU Panels. Panels was connectd by the type of ecentric locks with better air tightness close and better insulation effect. It also has the disassembling easilly, can be lexible mobile etc. Such kind of cold storage can be assembled to be different size and capacity on different places.

Cold Storage Panel Standard

 

NO.

Base Plate Thickness

Applicable Temperature Range

1

50mm

High temperature (5°c or above )

2

75mm

 Medium temperature (-5°c or above)

3

100mm

 Low temperature (-30 °c  or above)

4

150mm

 Ultra Low temperature (-45 °c or above)

 

According  to the different requirements of customers, refrigerator production use different material combination, the cold storage floor interior surface and buried steel or wood quare, rinforcement, so as to adapt to replenish one's stock in the heavy truck driving r bear the weight of the shelf. Some cold storge directly using strip PU do bottom, in its upper berth on a certain thickness of cement to make a floor board, such already strong and durable, sultable for hotel ktchen.

Cold Storage Panel Option  (by different material):

 

 Panel Details:

 

1. Panel Width Available: 295.30mm, 590.60mm, 885.80mm and 1181.10mm

 

2. Panel Length Available: Any length but not exceed to 12000mm

 

3. Regular Steel Sheet Color Code: RAL 9002(Grey White)

 

4. PU Density: 32-50 KGS/M3

 

5. Heat Transfer Coefficient: 0.024 W/M*K

 

6. Bending Strength: 331Mpa 

 

7. Fire Rating: B2

 

8. Surface of Panels: Can choose any kind of the surface materials.

 

 

Referred to inspection sandard on use of heat insulation sandwich panel in composite cold storage in nationa machinery industry standard JB/T6527~2006, cold storage panel should be in accordance with the following technical conditions.

 

 

Feature Project

Unit

Technical Requirements

Test Results

Average Density

Kg/m3

38~42

40

Heat Conductivity Coefficient

W/m. k

≤0.024

≤0.021

Compression Strength

Kpa

≥160

≥ 171

 

FAQ:

A, Could be changed the size of the panel?

    Yes, we design the size according to your requirement.

B, What is the color of the panel?

     All the colors in "RAUL"