1. Structure of Solar Photovoltaic On-Grid Connected Inverter SG20KTL Description
A solar inverter, or PV inverter, or Solar converter, converts the variable direct current (DC) output of a photovoltaic (PV) solar panel into
autility frequency alternating current (AC) that can be fed into a commercial electrical grid or used by a local, off-grid electrical network.
It is acritical BOS–component in a photovoltaic system, allowing the use of ordinary AC-powered equipment. Solar inverters have
special functions adapted for use with photovoltaic arrays, including maximum power point tracking and anti-islanding protection.
Suitable for 50Hz/60Hz grid, could be used in Asia, Africa and Europe. Available for hand installation, no need for lifting machinery
assistance.
2. Main Features of the Photovoltaic On-Grid Connected Inverter SG20KTL
• Full 20 kW effective power at power factor of 0.9 due to apparent power reserves up to 22.2 kVA
• Photon test results "very good", with a maximum efficiency of 98% (Photon Profi 2-2012)
• Dual MPP trackers control
• Active power continuously adjustable (0~100%)
•Reactive power control with power factor 0.8 overexcited ~ 0.8 underexcited
•Includes RS-485 interface, compatible with all common monitoring systems
• Product certification: TÜV, CE, CEI 0-21, G59/2, AS4777, BDEW, VDE AR-N-4105, CGC, compliance with Italian medium voltage grid requirement
• Manufacturer certification: ISO 9001, ISO 14001, OHSAS 18000
3. Photovoltaic On-Grid Connected Inverter SG20KTL Images
4. Photovoltaic On-Grid Connected Inverter SG20KTL Specification
Input Side Data | |
Max. PV input power | 21000W(10500W/10500W) |
Max. PV input voltage | 1000V |
Startup voltage | 300V |
Nominal input voltage | 620V |
MPP voltage range | 280~950V |
MPP voltage range for nominal power | 480~800V |
No. of MPPTs | 2 |
Max. number of PV strings per MPPT | 3 |
Max. PV input current | 42A(21A/21A) |
Max. current for input connector | 12A |
Output Side Data | |
Nominal AC output power | 20000W |
Max AC output power(PF=1) | 22200W |
Max. AC output apparent power | 22200VA |
Max. AC output current | 33A |
Nominal AC voltage | 3/N/PE, 230/400Vac |
AC voltage range | 310~480Vac |
Nominal grid frequency | 50Hz/60Hz |
Grid frequency range | 47~53Hz/57~63Hz |
THD | < 3 % (Nominal power) |
DC current injection | <0.5 %In |
Power factor | >0.99@default value at nominal power |
(adj. 0.8overexcited ~0.8underexited ) | |
Protection | |
Anti-islanding protection | Yes |
LVRT | Yes |
DC reverse connection protection | Yes |
AC short circuit protection | Yes |
Leakage current protection | Yes |
DC switch | Yes |
DC fuse | No |
Overvoltage protection | Varistors |
System Data | |
Max. efficiency | 98.00% |
Max. European efficiency | 97.30% |
Isolation method | Transformerless |
Ingress protection rating | IP65 |
Night power consumption | <1W |
Operating ambient temperature range | -25~60℃(>45℃ derating) |
Allowable relative humidity range | 0~100% |
Cooling method | Smart forced air cooling |
Max. operating altitude | 4000m (>3000m derating) |
Display | Graphic LCD |
Communication | RS485(RJ45 connector) |
DC connection type | MC4 |
AC connection type | Plug and play connector |
Certification | EN62109-1, EN62109-2, EN61000-6-2,EN61000-6-3, VDE0126-1-1, |
CEI 0-21, AS/NZS3100, AS4777.2, AS4777.3, | |
VDE-AR-N-4105, BDEW, CGC | |
Mechanical Data | |
Dimensions(W×H×D) | 648×686×246mm |
Mounting method | Wall bracket |
Weight | 55kg |
5. FAQ of Photovoltaic On-Grid Connected Inverter SG20KTL
Q1. What is the difference between inverter and solar inverter?
A1. Inverter only has AC inpput, but solar inverter both connect to AC input and solar panel, it saves more power.
Q2. What is the difference between MPPT&PWM?
A2. MPPT has higher efficiency, it can track the max power point and won't waste energy.