. 2KW/3KW/5KW on-grid inverter with energy storage
. Pure sine wave output
. Microprocessor controlled to guarantee stable charging system
. Multiple operations: Grid tie, Off grid, and grid-tie with backup
. Built-in MPPT solar charger
. LCD display panel for comprehensive information
. Multiple communication
. Green substitution for generators
. User-adjustable battery charging current
On-grid PV Inverter with Energy Storage – PH500 3KW
Model | PH500 Single-phase 2KW | PH500 Single-phase 3KW | |
RATED POWER | 2000 W | 3000 W | |
GRID-TIE OPERATION | |||
PV INPUT (DC) | |||
Maximum DC Power | 2250W | 3200W | |
Nominal DC Voltage / Maximum DC Voltage | 300 VDC / 350 VDC | 360 VDC / 500 VDC | |
Start-up Voltage / Initial Feeding Voltage | 80 VDC / 120 VDC | 116 VDC / 150 VDC | |
MPP Voltage Range | 150 VDC ~ 320 VDC | 250 VDC ~ 450 VDC | |
Number of MPP Trackers / Maximum Input Current | 1 / 1 x 15 A | 1 / 1 x 13 A | |
GRID OUTPUT (AC) | |||
Nominal Output Voltage | 101/110/120/127 VAC | 208/220/230/240 VAC | |
Output Voltage Range | 88 - 127 VAC* | 184 - 264.5 VAC* | |
Nominal Output Current | 18 A | 13.1 A* | |
Power Factor | > 0.99 | ||
EFFICIENCY | |||
Maximum Conversion Efficiency (DC/AC) | 95% | 96% | |
European Efficiency@ Vnominal | 94% | 95% | |
OFF-GRID OPERATION | |||
AC INPUT | |||
AC Start-up Voltage/Auto Restart Voltage | 60 - 70 VAC / 85 VAC | 120 - 140 VAC / 180 VAC | |
Acceptable Input Voltage Range | 85 - 130 VAC* | 170 - 280 VAC | |
Number of MPP Trackers / Maximum Input Current | 30 A | 25 A | |
PV INPUT (DC) | |||
Maximum DC Voltage | 350 VDC | 500 VDC | |
MPP Voltage Range | 150 VDC ~ 320 VDC | 250 VDC ~ 450 VDC | |
Maximum Input Current | 1 / 1 x 15 A | 1 / 1 x 13 A | |
BATTERY MODE OUTPUT (AC) | |||
Nominal Output Voltage | 101/110/120/127 VAC | 208/220/230/240 VAC | |
Output Waveform | Pure Sinewave | ||
Efficiency (DC to AC) | 90% | 93% | |
HYBRID OPERATION | |||
PV INPUT (DC) | |||
Nominal DC Voltage / Maximum DC Voltage | 300 VDC / 350 VDC | 360 VDC / 500 VDC | |
Start-up Voltage / Initial Feeding Voltage | 80 VDC / 120 VDC | 116 VDC / 150 VDC | |
MPP Voltage Range | 150 VDC ~ 320 VDC | 250 VDC ~ 450 VDC | |
Maximum Input Current | 1 / 1 x 15 A | 1 / 1 x 13 A | |
GRID OUTPUT (AC) | |||
Nominal Output Voltage | 101/110/120/127 VAC | 208/220/230/240 VAC | |
Output Voltage Range | 88-127 VAC | 184 - 264.5 VAC | |
Nominal Output Current | 18 A | 13.1 A* | |
AC INPUT | |||
AC Start-up Voltage/Auto Restart Voltage | 60 - 70 VAC / 85 VAC | 120 - 140 VAC / 180 VAC | |
Acceptable Input Voltage Range | 80 - 130 VAC* | 170 - 280 VAC | |
Maximum AC Input Current | 30 A | 25 A | |
BATTERY MODE OUTPUT (AC) | |||
Nominal Output Voltage | 101/110/120/127 VAC | 208/220/230/240 VAC | |
Efficiency (DC to AC) | 90% | 93% | |
BATTERY & CHARGER | |||
Nominal DC Voltage | 48 VDC | 48 VDC | |
Maximum Charging Current | 25A | 25A | |
GENERAL | |||
PHYSICAL | |||
Dimension, D x W x H (mm) | 420 x 415 x 170 | ||
Net Weight (kgs) | 15.5 | ||
INTERFACE | |||
Communication Port | RS-232/USB | ||
Intelligent Slot | Optional SNMP, Modbus, and AS-400 cards available | ||
ENVIRONMENT | |||
Humidity | 0 ~ 90% RH (No condensing) | ||
Operating Temperature | 0 to 40°C | ||
Altitude | 0 ~ 1000 m** |
Warranty
provides a 1~3 year limited warranty (“Warranty”) against defects in materials and workmanship for its Uninterruptible power supply, Power inverter/chargers, Solar charge controllers, Battery Products (“Product”).
The term of this Warranty begins on the Product(s) initial purchase date, or the date of receipt of the Product(s) by the end user, whichever is later. This must be indicated on the invoice, bill of sale, and/or warranty registration card submitted to MUST-Solar. This Warranty applies to the original MUST-Solar Product purchaser, and is transferable only if the Product remains installed in the original use location.
FAQ
1. How do I decide which system is right for me ?
For protection from long outages, include a generator or solar panels in your Must solar system. Shorter outages can be handled by a battery-only system.
2. Where my system will be installed ?
Must solar systems are usually wall-mounted near a home's main electrical (circuit breaker) panel.
3. How do I install my system ?
A must solar backup inverter is connected to a home electric system , we will supply detailed installation manual and videos for our customers .