4.2 Kw Off-Grid Low Frequency PV Inverter EP3200 Series 1Kw-3Kw

Loading Port:China main port

Payment Terms:TT or LC

Min Order Qty:30000 watt

Supply Capability:18000000 watt/month

Product Description:

 

 

1. Structure of Off-Grid Low Frequency PV Inverter Description

A solar inverter, or PV inverter, or Solar converter, converts the variable direct current (DC) output of a photovoltaic (PV) solar panel into a

utility frequency alternating current (AC) that can be fed into a commercial electrical grid or used by a local, off-grid electrical network. It is a

critical BOS–component in a photovoltaic system, allowing the use of ordinary AC-powered equipment. Solar inverters have special

functions adapted for use with photovoltaic arrays, including maximum power point tracking and anti-islanding protection..

 

2. Main Features of the Off-Grid Low Frequency PV Inverter

• High overload ability of our EP3200 charger is up to 300% rated power

• EP3200 pure sine wave inverter adopts low quiescent current, and power saver mode to reduce power consumption to 3W

• It can extract max• power from various batteries with different protections, and low voltage trip can be selected (10V/10. 5V/11V)

• Uses PFC (power factor correction) for charger, which has less power consumption than conventional units.

• It has 10s delay before transfer when AC resumes, and overload protection when our APC pure sine wave inverter equips with generator

• 10ms typical transfer time between battery and AC, which guarantees power continuity of EP3200 charger. Uses selectable input AC

voltage (185-265V or 155-255V) for different kinds of loads

• Our EP3200 charger allows start up and through power with depleted batteries. Its powerful charge rate up to 70Amp

• It can offer 3-step intelligent battery charging, and equipped with 6 preset battery type selector for totally flat batteries

• LCD status display, battery/AC priority switch, RS232 communication port are available for our EP3200 pure sine wave inverter, it also has

 17 alarms/warnings for easier operation and trouble-shooting, and ability to switch the unit on/off. In addition, select/deselect power saver

mode can be used too

 

3. Off-Grid Low Frequency PV Inverter Images

Off-Grid Low Frequency PV Inverter EP3200 Series 1KW-3KW

Off-Grid Low Frequency PV Inverter EP3200 Series 1KW-3KW

Off-Grid Low Frequency PV Inverter EP3200 Series 1KW-3KW

Off-Grid Low Frequency PV Inverter EP3200 Series 1KW-3KW

 

 

4. Off-Grid Low Frequency PV Inverter Specification

Rated Capacity

1000W 

1500W 

2000W 

3000W 

Efficiency

>90%

Input

Model

120v Models

230v Models

Nominal Voltage

100V/110V/115V/120V Selectable

200V/220V/230V/240V Selectable

Output

Rated Power

1000W

1500W

2000W

3000W

Output Voltage

100V/110V/115V/120V Selectable

200V/220V/230V/240V Selectable

Voltage Waveform

Pure Sine Wave

Crest Factor

3:01

Regulation(Nominal)

±10% Typical Of Nominal Voltage

Transfer Time

Transfer Time : AC To DC : 10ms (Typical)

Transfer Time : DC To AC : 10ms(Typical )

Max Bypass Overload Current

30A

Input

Nominal Voltage

DC12V/24V

DC12V/24V

DC12V/24V

DC24V/48V

Over Current Protection

By Re-Settable Over Current Protector

Output

Nominal Input Voltage

230Vac

Input Voltage Range

185~265Vac

Nominal Charge Current

35amp-70amp

Charger Short

Circuit Breaker

Circuit Protection

Over Charge

Bat• V  15• 7Vdc/31• 4Vdc/62• 8Vdc

Protection

Beeps 0• 5s Every 1s & Fault After 60s

Battery Type

Lead-Acid 12Ah 250Ah

Typical Backup Time

No Limit, Depend on external battery

Average Charging Current

35A/20A

45A/30A

65A/35A

75A/30A

Battery voltage Option

Options 7

Battery low trip to bypass 11v , high trip to battery 14v

Options 8

Battery low trip to bypass 10• 5v , high trip to battery 13• 5v

Options 9

Battery low trip to bypass 10v , high trip to battery 13v

Communications & Management 

Control Panel

LCD/LED Option

Audible Alarm

Alarm On BatteryLow Battery & Battery Over Voltage

Alarm On Abnormal Operation

Over Load, Short-Circuit, & Over Heat

Environment and Safe

Operating Temperature

0 To 40 (32 To 104)

Transit/Storage Temperature

-15 To 60

Audible Noise

60 Dba Max at 1m

Quality Control System

ISO 9001,CE,FCC

Physical

Dimensions: (H×D×W)

570*320*315mm

G• W (Kg)

19

19

22.5

27.5

Packing

Export Carton For Each Unit Per Carton

 

5. FAQ of Off-Grid Low Frequency PV Inverter

 

Q1 What is the difference between inverter and Off-Grid Low Frequency PV Inverter?
A1Inverter only has AC inpput, but Off-Grid Low Frequency PV Inverter both connect to AC input and solar panel, it saves more power.

 

Q2 What is the difference between MPPT&PWM?
A2MPPT has higher efficiency, it can track the max power point and won't waste energy.

 

Q3 What is the waranty of product?
A3 12 months.