Plastic Fishing Net Floats Non Woven Geotextile for Dam Long Fiber

Loading Port:China Main Port

Payment Terms:TT OR LC

Min Order Qty:-

Supply Capability:-

Product Description:

NON-WOVEN GEOTEXTILE

Introduction of Non-woven Geotextile:
Non-woven Geotextiles, characterized by excellent water permeability, filtration, and durability, The product mainly includes short filament needle non-woven geotextile and split film filament woven geotextile.

Specification of NON-Woven Geotextile :

Width : From 1~ 8m

Length: 50-100m as customer requests.

Weight : 100gsm~ 1500gsm

Color : black ,white , grey ,other colors are available

Packaging & Delivery

Packaging Details:according to customer's requirement or standard package
Delivery Detail:7~10 days

Specifications

High tensile strength in warp and across directions
low elongation
high flexibility
high and low temperature resistance

Product Details

Application: This product is used to strengthen the soft land, such as railway, airport, irrigation work, and dyke, roadbed, and softland loading capacity strengthen.

Properties of Fiberglass Geogrid

Specification

EGA30-30

EGA50-50

EGA80-80

EGA100-100

EGA120-120

Mesh size(mm)

25.4×25.4 Or 12.5×12.5

Breaking strength

≥(KN/m)

Warp direction

30

50

80

100

120

Across warp

30

50

80

100

120

Elongation at break

≤(%)

Warp direction

3

Across warp

3

Elasticity modulus(GPA)

67

Thermal tolerance

-100~280°C

Width

1~6m

Short Fiber Punched Geotextile

Technical data sheet for Short Fiber Punched NON Woven Geotextile :

 
Product specifications and performance parameters (ie, National standard GB/T17638-1998)

No.

Item \ Indicator \ specification

100

150

200

250

300

350

400

450

500

600

800

Remarks

1

Mass area ratio deviation%

-8

-8

-8

-8

-7

-7

-7

-7

-6

-6

-6

 

2

Thicknessmm ≥

0.9

1.3

1.7

2.1

2.4

2.7

3.0

3.3

3.6

4.1

5.0

 

3

Amplitude, deviation%

-0.5

 

4

Breaking strengthKN/m ≥

2.5

4.5

6.5

8.0

9.5

11.0

12.5

14.0

16.0

19.0

25.0

Vertical and horizontal direction

5

Elongation at break%

25100

6

CBR bursting strengthKN ≥

0.3

0.6

0.9

1.2

1.5

1.8

2.1

2.4

2.7

3.2

4.0

 

7

Equivalent aperture,mm

0.070.2

 

8

Vertical permeability coefficient,cm/s

Kx(10-1 10-3 )

K=1.0 9.9

9

Tear strengthKN≥

0.08

0.12

0.16

0.20

0.24

0.28

0.33

0.38

0.42

0.46

0.60

Vertical and horizontal direction