Product Name | NDM3E Series Electronic MCCB |
Standards and Certificates | IEC60947-1; IEC60947- 2 |
Rated Voltage | AC 400V |
Rated Current | 32A~800A |
Breaking Capacity | 50kA~100kA@AC 400V 50Hz |
Isolation Function | Yes |
Number of Poles | 3 Poles, 4 Poles |
Tripping Characteristics | / |
Mechanical Endurance | 20000 times (for NDM3E-125, NDM3E-250), 15000 times (for NDM3E-400), 10000 times (for NDM3E-630,NDM3E-800) |
Wiring Capacity | / |
Electric Accessories | Auxiliary Switch, Alarm Switch, Shunt Release, Under-voltage Release |
Specifications
· Standard: IEC60947-1; IEC60947- 2
· Rated Voltage: AC 400V
· Rated Current: 32A~800A
· Number of Poles: 3, 4
· Mechanical Life (With maintenance): 20000 times (for NDM3E-125, NDM3E-250);
10000 times (for NDM3E-400, NDM3E-630);
5000 times (for NDM3E-800).
· Rated Ultimate Breaking Capacity Icu AC 50Hz 400V: 50kA~100kA
· Rated Operating Short Circuit Breaking Capacity Ics AC 50Hz 400V: 35kA~65kA
Features
· Communication function: The breaker can be connected with computer to realize remote control, remote-adjust, remote-meter and remote-information.
· Overload alarm non-tripping function: The breaker is with overload alarm non-tripping function. Once the breaker is set with this function, it will not trip when there is overload. Overload signal will be sent through output node to ensure continuity of power supply.
· Protective function against grounding fault: The breaker with protective function against grounding fault can protect the circuit against grounding fault.
· Rapid installing internal accessories: The whole series product can be equipped with modular accessories rapidly.
· 3-segment protection functions: The breaker can provide protection functions against overload, short-circuit with delayed trip and short-circuit withinstantaneous trip. It can be adjusted by customers.
· Self-power: Intellectual controller is powered by circuit breaker itself.
· Pre-alarm indication: LED "Alarm" on the panel flashes and then lights solid when the actual current reaches or exceeds pre-alarm tripping threshold Ip.
· Overload indication: LED "Over" lights solid when the load current exceeds long-time overload tripping threshold.
· Instantaneous tripping function at large current: Breaker is tripped directly by electromagnetic trip unit when there is large current during operation.
· Various connection types and accessories available.