Loading Port:Wenzhou
Payment Terms:TT OR LC
Min Order Qty:-
Supply Capability:10000pcs PCS/month
Technical Data |
◆Number of poles:1,2,3,4,1+N,3+N ◆Nominal current In(A): 1,2,3,4,6,8,10,13,16,20,25,32,40,50,63 ◆Characteristics: ◇B The short-circuit release is to be set up to 3 In through 5 In.It serves especially for protection of circuits with such devices which do not cause any current surges(lights or socket circuits etc.) ◇C The short-circuit release is to be set up to 5 In through 10 In.It serves especially for protection of circuits with such devices which cause some current surges(groups of bulbs, motors etc.) ◇D The short-circuit release is to be set up to 10 In through 20 In. It serves especially for protection of circuits with devices which cause high current surges(transformers,double-pole motors,motors with heavy start etc.) ◆Nominal voltage: ◇1P (single-pole)~230/400V 50/60Hz ◇3P (three-pole)~400V 50/60Hz ◆Rupturing capacity: ◇EN60898-10,000A(nominal short-circuit and operational rupturing capacity) ◆Protection:IP40 for a sole MCB with its design, it protects against a hazardous finger or instrument touch as well as against very small foreign objects; It is without any protection against water leakage (water protection is to be solved with design of the switchboard casing) ◆Ambient temperatue: -5oC to +40oC pursuant to EN60898 ◆Gauging temperature:+30oC pursuant to EN60898 ◆Max.pre-inserted fuse:100AgG(>10kA) ◆Mechanical lifetime:≤20,000 cycles ◆Electrical lifetime:≤8,000 cycles ◆Fastening:By means of an unique snap mechanism(with arrestment in final positions)the carrying DIN strip EN50022,width 35mm, or even onto the falt surface by means of screws. ◆Removal form the DIN strip: ◇By means of an unique auxiliary snap mechanism, the MCB誷 can be removed even from a row of devices mutually interconnected by a forked or reed rack strip without necessity to dismantle the whole interconnecting strip. |
◆Input terminals: ◇Clip terminals(with barrier layer), snap-locked against the worse input of a conductor ◇The input and output can be interchanged ◇They enable more conductors as well as interconnecting strips to be connected ◆Connect ability of conductors (Maximum cross-sections): ◇35mm2 solid conductor ◇25mm2 stranded conductor ◆Terminal protection:IP20 ◆Tightening moment for terminals ◇2Nm(combined slotted-head screw) ◆Manufacture standard ◇EN60898,same to IEC 60898 ◆Selectivity calss:3 ◆Colored levers: For better distinction among circuits in the switchboards,we supply also miniature circuit breaker with distinction of nominal currents by means of colored levers corresponding to the colors of turn fuses ◇0.2A-1.6A(Black) ◇2A(Pink) ◇4A(Brown) ◇6A(Green) ◇8A(Light green) ◇10A(Red) ◇13A(Sandy) ◇16A(Grey) ◇20A(Blue) ◇25A(Yellow) ◇32A(Purple) ◇40A(Black) ◇50A(White) ◇63A(Copper-colored) ◆Can be delivered also with only black levers ◇1-63(Black) |