Mine used Cable all different kinds of rubber insulated flexible mine

Loading Port:Shanghai

Payment Terms:TT OR LC

Min Order Qty:100 m

Supply Capability:100000 m/month

Product Description:

Application

    This  product is suitable for using as all different kinds of rubber  insulated flexible mine used cable with A.C voltage of 6 kV and below.

Type and Designation


Designation

Standard

GB/T12972.110-1991

MT818.110-1999

Type

Coal excavator used rubber covered    flexible cable

UC-0.38/0.66

MC-0.38/0.66

Coal excavator shielded rubber covered  flexible cable

UCP-0.38/0.66

UCP-0.66/1.14

MCP-0.38/0.66

MCP-0.66/1.14

MCP-1.9/3.3

Coal excavator metal shielded rubber   covered  flexible cable

UCPT-0.66/1.14

MCPT-1.9/3.3

Coal excavator metal shielded supervising rubber covered  flexible cable

——

MCPTJ-1.9/3.3

MCPTJ-0.66/1.14

Coal excavator shielded supervising   braided enhanced rubber covered    flexible cable

UCPJB-0.66/1.14

MCPJB-0.66/1.14

Coal excavator shielded supervising   wrapping enhanced rubber covered    flexible cable

UCPJR-0.66/1.14

MCPJR-0.66/1.14

Mine electric driller used rubber   covered  cable

UZ-0.3/0.5

MZ-0.3/0.5

Mine shielding electric driller rubber   covered  cable

UZP-0.3/0.5

MZP-0.3/0.5

Mine moving rubber covered  flexible cabel

UY-0.38/0.66

MY-0.38/0.66

Mine moving shielding rubber covered    flexible cable

UYP-0.38/0.66

UYP-0.66/1.14

MYP-0.38/0.66

MYP-0.66/1.14

Mine moving metal shielding rubber   covered flexible cable

UYPT-3.6/6

MYPT-1.9/3.3

MYPT-3.6/6

Mine moving metal shielding supervising   rubber covered flexible cable

UYPJ-3.6/6

MYPTJ-3.6/6

Mine moving light duty rubber covered   flexible cable

UYQ-0.3/0.5

MYQ-0.3/0.5

Mine worker cap used cable

UM

UM-1

MM


Technical parameter

1At 20 D.C resistance of the category 5 tining flexible conductor should comply with requirement of GB/T3956.

2Electrical insulating performance

Insulating resistance constant Ki shall not exceed 180MΩ·km at 20℃;

Power frequency A.C voltage test:

Type of the insulation core

Rated voltage

kV

Testing voltage (virtual value)

kV

Time of operating voltage

min

Driving core

3.6/6

11.0

5

1.9/3.3

6.8

0.66/1.14

3.7

0.38/0.66

3.0

0.3/0.5

2.0

Control core

1.5

3、  Coal  excavator used rubber flexible cable and mine used moving flexible  cable with voltage of 1.9/3.3kV and below shall have the following  performance:

Times of mechanical resistant impact shall be

Nominal cross-section16mm235mm2···············2 times

Nominal cross-section50mm295mm2···············3 times

Pressure of press resitstant

U0/U0.38/0.66kV····························20kN

0.66/1.14kV····························30kN

1.9/3.3 kV····························40kN

4、  Coal  excavator used rubber flexible cable with voltage of 1.9/3.3 kV and  below shall have the bending resistant performance, it shall not cause  circuit breakdown and short circuit after 9000 times bend.

Feature

Coal  mine used cable has good impact, bending and press resistant  performance, especially the fire resistant and flame-retardant  characteristic. It also has operating secure and good earthing  performance.