Abb Solar Inverter Micro-Inverter BDM-300

Loading Port:Qingdao

Payment Terms:TT OR LC

Min Order Qty:10 unit

Supply Capability:1000 unit/month

Product Description:

Description:

 

A solar micro-inverter, converts direct current (DC) electricity from a single solar panel to alternating current (AC). The electric power from several micro-inverters is combined and fed into an existing electrical grid. Micro-inverters contrast with conventional string or central inverter devices, which are connected to multiple solar panels.

 

Characteristic & Advantages:

More Energy Harvest: Distributed MPPT allows10~25% more energy harvest
Simple: Modularized,single ac cable to the house
Reliability: Longer life time and almost 100% operation hours
Security: No high Voltage, makes safter environments
Inteligent : Monitoring each module
Savings: No dc components and significantly save labor cost

 

Micro-Inverter BDM-300 

MODEL

BDM-300-240A

BDM-300-208A

BDM-300-EU

BDM-300-AU

INPUT(DC)

Max Recommended PV Power (Wp)

310

Max DC Open Circuit Voltage (Vdc)

60

Max DC Input Current (Adc)

12

MPPT Tracking Accuracy

>99.5%

MPPT Tracking Range (Vdc)

22-55

Isc PV (absolute maximum) (Adc)

14

140

Maximum Inverter Backfeed Current to the Array (Adc)

0

0

OUTPUT(AC)

Rated AC Output Power (Wp)

250

Nominal Power Grid Voltage (Vac)

240

208

230

Allowable Power Grid Voltage (Vac)

211-264*

183-229*

configurable

Allowable Power Grid Frequency (Hz)

59.3-60.5*

configurable

THD

<3% (at rated power)

/

Power Factor (cos phi, fixed)

>0.99 (at rated power)

Current (maximum continuous) (Aac)

1.2

Current (inrush) (Peak and Duration)

12A, 15us

Nominal Frequency (Hz)

60

50

Maximum Output Fault Current (Aac)

2.2A peak

Maximum Output Overcurrent Protection (Aac)

6.3

Maximum Number of Units Per Branch

16 (12AWG); 12 (14AWG)

SYSTEM EFFICIENCY

Peak Efficiency

96.30%

96.30%

95.80%

CEC Efficiency

95.5%

Night Time Tare Loss (Wp)

0.08

0.06

0.07

PROTECTION FUNCTIONS

Over/Under Voltage Protection

Yes

Over/Under Frequency Protection

Yes

Anti-Islanding Protection

Yes

Over Current Protection

Yes

Reverse DC Polarity Protection

Yes

Overload Protection

Yes

Protection Degree

NEMA-6 / IP-67

I

Environment Temperature

-40℃——+65℃

OTHER PARAMETERS

Environment Humidity

100%, condensation

Display

LED LIGHT

Communications

Power Line

Dimension (D-W-H mm)

180*186*25

Weight (Kg)

1.5

Environment Category

Indoor and outdoor

Wet Location

Suitable

Pollution Degree

PD 3

Maximum Altitude

2000 M

Overvoltage Category

II(PV), III (AC MAINS)

Product Safety Compliance

UL 1741

CSA C22.2 No. 107.1

IEC/EN 62109-1

IEC/EN 62109-2

Grid Code Compliance* (Refer to the label for the detailed grid code compliance)

IEEE 1547

VDE-AR-N 4105*

VDE V 0126-1-1/A1

G83/2, CEI 021

AS 4777.2 & AS 4777.3

 

 

Note:

For grid code VDE-AR-N 4105, maximum 3.68kVA PV plant is limited. The grid protection report and setting are readable from the gateway.

For grid code G83/2, maximum 16A per phase is limited. The grid protection report and setting are readable from the gateway.

Grid parameters are configurable through the BDG-256 gateway.