Loading Port:Qingdao
Payment Terms:TT OR LC
Min Order Qty:10 unit
Supply Capability:1000 unit/month
Description:
A solar micro-inverter, converts direct current (DC) electricity from a single solar panel to alternating current (AC). The electric power from several micro-inverters is combined and fed into an existing electrical grid. Micro-inverters contrast with conventional string or central inverter devices, which are connected to multiple solar panels.
Characteristic & Advantages:
More Energy Harvest: Distributed MPPT allows10~25% more energy harvest
Simple: Modularized,single ac cable to the house
Reliability: Longer life time and almost 100% operation hours
Security: No high Voltage, makes safter environments
Inteligent : Monitoring each module
Savings: No dc components and significantly save labor cost
MODEL | BDM-300-240A | BDM-300-208A | BDM-300-EU BDM-300-AU | |||
INPUT(DC) | Max Recommended PV Power (Wp) | 310 | ||||
Max DC Open Circuit Voltage (Vdc) | 60 | |||||
Max DC Input Current (Adc) | 12 | |||||
MPPT Tracking Accuracy | >99.5% | |||||
MPPT Tracking Range (Vdc) | 22-55 | |||||
Isc PV (absolute maximum) (Adc) | 14 140 | |||||
Maximum Inverter Backfeed Current to the Array (Adc) | 0 0 | |||||
OUTPUT(AC) | Rated AC Output Power (Wp) | 250 | ||||
Nominal Power Grid Voltage (Vac) | 240 | 208 | 230 | |||
Allowable Power Grid Voltage (Vac) | 211-264* | 183-229* | configurable | |||
Allowable Power Grid Frequency (Hz) | 59.3-60.5* | configurable | ||||
THD | <3% (at rated power) / | |||||
Power Factor (cos phi, fixed) | >0.99 (at rated power) | |||||
Current (maximum continuous) (Aac) | 1.2 | |||||
Current (inrush) (Peak and Duration) | 12A, 15us | |||||
Nominal Frequency (Hz) | 60 | 50 | ||||
Maximum Output Fault Current (Aac) | 2.2A peak | |||||
Maximum Output Overcurrent Protection (Aac) | 6.3 | |||||
Maximum Number of Units Per Branch | 16 (12AWG); 12 (14AWG) | |||||
SYSTEM EFFICIENCY | Peak Efficiency | 96.30% | 96.30% | 95.80% | ||
CEC Efficiency | 95.5% | |||||
Night Time Tare Loss (Wp) | 0.08 | 0.06 | 0.07 | |||
PROTECTION FUNCTIONS | Over/Under Voltage Protection | Yes | ||||
Over/Under Frequency Protection | Yes | |||||
Anti-Islanding Protection | Yes | |||||
Over Current Protection | Yes | |||||
Reverse DC Polarity Protection | Yes | |||||
Overload Protection | Yes | |||||
Protection Degree | NEMA-6 / IP-67 I | |||||
Environment Temperature | -40℃——+65℃ | |||||
OTHER PARAMETERS | Environment Humidity | 100%, condensation | ||||
Display | LED LIGHT | |||||
Communications | Power Line | |||||
Dimension (D-W-H mm) | 180*186*25 | |||||
Weight (Kg) | 1.5 | |||||
Environment Category | Indoor and outdoor | |||||
Wet Location | Suitable | |||||
Pollution Degree | PD 3 | |||||
Maximum Altitude | 2000 M | |||||
Overvoltage Category | II(PV), III (AC MAINS) | |||||
Product Safety Compliance | UL 1741 CSA C22.2 No. 107.1 | IEC/EN 62109-1 IEC/EN 62109-2 | ||||
Grid Code Compliance* (Refer to the label for the detailed grid code compliance) | IEEE 1547 | VDE-AR-N 4105* VDE V 0126-1-1/A1 G83/2, CEI 021 AS 4777.2 & AS 4777.3
| ||||
Note: For grid code VDE-AR-N 4105, maximum 3.68kVA PV plant is limited. The grid protection report and setting are readable from the gateway. For grid code G83/2, maximum 16A per phase is limited. The grid protection report and setting are readable from the gateway. Grid parameters are configurable through the BDG-256 gateway. |