Evacuated Tube Solar Collectors Metal Glass Heat Pipe Model SC-HM

Loading Port:Shanghai

Payment Terms:TT OR LC

Min Order Qty:20 set

Supply Capability:1500 set/month

Product Description:

1. Structure of Metal Glass Heat Pipe for Solar Collector  Model SC-HM

   This Metal Glass Heat Pipe is an important part for solar collector, and the components are following as shown with graphic:

  

Metal Glass Heat Pipe for Solar Collector  Model SC-HMMetal Glass Heat Pipe for Solar Collector  Model SC-HM

 

1 Manifold

2 Inlet & Outlet

3 Bracket

4 Metal Glass Vacuum Tube

5 Pipe Supporter

6 Anti-wind Foot

  

2. Main Features of Metal Glass Heat Pipe for Solar Collector  Model SC-HM 

 

3. Metal Glass Heat Pipe for Solar Collector  Model SC-HM Images

 

 

Metal Glass Heat Pipe for Solar Collector  Model SC-HM

Metal Glass Heat Pipe for Solar Collector  Model SC-HM

 

4. Metal Glass Heat Pipe for Solar Collector  Model SC-HM Specifications

 

Model No.

SC-HM-10

SC-HM-15

SC-HM-18

SC-HM-20

SC-HM-24

SC-HM-25

SC-HM-30

No.of Vacuum Tube(PCS)

10

15

18

20

24

25

30

Tube Space(㎜)

100

100

100

100

100

100

100

OD/L of Vacuum Tube(㎜)

φ70/2000

φ70/2000

φ70/2000

φ70/2000

φ70/2000

φ70/2000

φ70/2000

Material of Vacuum Tube

Borosilicate glass 3.3

Borosilicate glass 3.3

Borosilicate glass 3.3

Borosilicate glass 3.3

Borosilicate glass 3.3

Borosilicate glass 3.3

Borosilicate glass 3.3

Material/Thickness of Heat Pipe(㎜)

Coppertp2/0.6

Coppertp2/0.6

Coppertp2/0.6

Coppertp2/0.6

Coppertp2/0.6

Coppertp2/0.6

Coppertp2/0.6

OD/Thickness of Flow Chute(㎜)

φ35/1.0

φ35/1.0

φ35/1.0

φ35/1.0

φ35/1.0

φ35/1.0

φ35/1.0

OD of Outlet & Inlet

φ22 or 3/4″

φ22 or 3/4″

φ22 or 3/4″

φ22 or 3/4″

φ22 or 3/4″

φ22 or 3/4″

φ22 or 3/4″

Insulation Material/Thickness(㎜)

Rockwool/40

Rockwool/40

Rockwool/40

Rockwool/40

Rockwool/40

Rockwool/40

Rockwool/40

Working Pressure(MPa)

0.6

0.6

0.6

0.6

0.6

0.6

0.6

Working Temp ℃

<150

<150

<150

<150

<150

<150

<150

Capacity of Solar Collector(L)

0.69

0.98

1.15

1.27

1.50

1.56

1.85

Collecting Area(㎡)

1.37

2.05

2.46

2.73

3.28

3.41

4.10

Total Area(㎡)

2.20

3.28

3.92

4.35

5.21

5.43

6.50

Flow Rate(L/min)

1.06

1.49

1.79

2.0

2.4

2.5

3.0

drop of pressure (Pa)

16.24

41.4

63.4

81.7

127.2

140.1

219.8

Intercept efficiency

η0

0.77

0.77

0.77

0.77

0.77

0.77

0.77

Heat loss rate a W/㎡℃

1.9

1.9

1.9

1.9

1.9

1.9

1.9

Efficiency(W)1000W/㎡irradiation

744

1044

1256

1398

1681

1748

2098

N.W(kg)

40.25

52.75

61.75

66.75

81.00

85.35

100.70

a   (㎜)

1115

1615

1915

2115

2515

2615

3115

b   (㎜)

1025

1525

1825

2025

2425

2525

3025

c   (㎜)

950

1450

1750

1950

2350

2450

2950

c/2 (㎜)

——

——

875

975

1175

1225

1475

d   (㎜)

2150

2150

2150

2150

2150

2150

2150

e   (㎜)

1375

1240

1240

1240

1240

1240

1240

f   (㎜)

1590

1590

1590

1590

1590

1590

1590

 

5. FAQ

 

1. What happens if one of the solar tubes is broken?
Firstly, tubes are very strong and not easily broken, but if the worst should happen, solar tubes can be replaced very easily. They are inexpensive and available. The solar collectors can operate with several broken tubes, but the efficiency will be reduced, so it is recommended that broken tubes be replaced immediately.

2. Can the solar collectors be mounted on a flat surface?
Yes they may be mounted on a flat roof or on the ground by using a stainless steel Flat Roof Frame. The collector should be installed at a minimum of 20o angle to ensure optimal operation of the heat pipe.

 

3. Will the solar collector be a fire hazard during hot, dry weather?
No. The solar collector's components are all high temperature rated and non-flammable, so even during strong sunlight with the circulation pump turned off (stagnation), the system will not catch alight or give off any sparks. The majority of the solar collector's components are stainless steel, aluminium, glass or glass wool. The manifold outlet should be fitted with a temperature relief valve, which will prevent the manifold temperature from exceeding 99oC / 212oF.