Low-Voltage XLPE Insulated power cable

Loading Port:China Main Port

Payment Terms:TT OR LC

Min Order Qty:-

Supply Capability:-

Product Description:

Specifications

1.up to 35kV available,factory direct sales
2. 20 years experience
3.OEM available provided

XLPE/PVC Insulated Power Cable  China Factory Supplier

Cable Construction

PVC Cable:


Cu(Al)/PVC/PVC Cable


Cu(AL)/PVC/SWA/PVC Cable


Cu(AL)/PVC/AWA/PVC Cable


Cu(Al)/PVC/STA/PVC Cable



XLPE Cable:


Cu(Al)/XLPE/PVC Cable


Cu(AL)/XLPE/SWA/PVC Cable


Cu(AL)/XLPE/AWA/PVC Cable


Cu(Al)/XLPE/STA/PVC Cable



Standard: IEC60502;BS5467:1997 with Amendment 1



Conductor: Soft annealed stranded copper wires to BS6360, class 2, concentrically stranded in successive layers, in opposite direction, to form the stranded conductor. Aluminum also available



Insulation:The conductor are insulated with a layer of extruded XLPE/PVC compound.



Filling:The assembled cable is filled with a layer of PVC compound in order to fill the interstices between the cores and render the cable round.



Armoring: Consists of single layer of Steel Tape/Galvanized steel wires of appropriate size.



Sheathing: An outer protection of extruded PVC compound is applied over the armor.



Voltage rating: 0.6/1kV,3.6/6kV;6/10KV;8.7/15KV;12/20KV;18/20KV;19/33KV;21/35KV;26/35KV



Operating temperature:

90 continuous normal operation, 130 for emergency overload condition and 250 for short circuit condition



Application:

For outdoor and indoor installations in damp and wet locations, laid direct in the ground where excessive mechanical stresses are present in sloping and moving terrains and in vertical or inclined laying, as well as in locations susceptible to sliding.



   

The data sheets below show partial  Type,Name and Application of  XLPE Insulated Power Cable:


Type Name

Application

Cu

Conductor

Al

Conductor

YJV

YJY

YJLV

YJLV

XLPE Insulated,PVC or PE S heathed Power CableFor laying in door,tunnel,channel and underground.Unable to bear external mechanical force,but bear the traction force during laid.

YJV22

YJV23

YJLV22

YJLV23

XLPE Insulated,Steel Tape Armoured,PVC or PE Sheathed Power Cable

For laying in tunels in door,tunnel,channel and underground.Able to bear external mechanical force,but unable to bear large pulling force.

YJV32

YJV33

YJLV32

YJLV33

XLPE Insulated,Fine Steel Wire Armoured,PVC or PE Sheathed Power Cable

For laying in shaft with large difference of level.Able to bear external mechanical force,and moderable pulling force.

YJV42

YJV43

YJLV42

YJLV43

XLPE Insulate,Thick Steel Wire Armoured,PVC or PE Sheathed Power Cable
Able to bear positive pressure and pulling force.


Packing:

Our advantage: