JKL607 Series Reactive Automatic Power Compensation Controller
Loading Port:China Main Port
Payment Terms:TT OR LC
Min Order Qty:-
Supply Capability:-
Product Description:
Applications
JKL607 series reactive automatic power compensation controller is designed according to the latest National standards of JB/T9663-1999,which is to be used together with low voltage electrostatic capacitance screen of various specifications,to provide real-time supervision on the power factor and reactive current of the power network,and give automatic throw-cut capacitor compensation to the power network. JKL607A/607B/607C adopts the high quality single chip computer of US Amy Company,wich provides power cut-off memory function.It also has other obvious features such as digitally display the power factor and voltage of power network,strong function,precise compensation,easy debug and so on. JKL607FA/JKL607FS adopts COMS digital integrated circuit and also use pointer meter to display the COSφ value.With manual operation function,you can use the manual operation button on the machine to switch on/off the compensation capacitor,while keeping the outpout state unchanged. JKLD607C adopts dynamic reactive power compensation controller designed by intel 16 digit single chip comuter,which outputs DC9-12V signal,controls dynamic reactive power compensation control switch(Type:JKLD607KC)or controls bi-dimensional thyristor of zero passage trigger and plate trigger to quickly switch the capacitor.(Zero passage disturbance free switch)
Structure Characteristics
1. No throw-cut vibration,precise control within the range of full loads. 2. The lock function in super low load. 3. Over voltage protection function. 4. Use the circular operation mode of the earlier throw off,the earlie cut off. 5. It has preset functions of voltage,time delay and power factor,and the preset parameters maintain even then the power is cut off .
Code and Its Meanings
Operation Conditions
1. Altitude:≤2000m 2. Ambient temperature:-15℃+~50℃. 3. Relative humidity:≤90% at 20℃,≤50% at 40℃, 4. Ambient environment:no flammable,explosive,electric conducting dust,or corrosive gas.
Main Technical Parameters
1. Rated Voltage:jkl607A/B/C 380V JKL607FA/FS 220V 2. Sample Airflow:≤5A 3. Throw-in threshold:0.85-0.98 4. Over voltage protection:400-440V 5. Time delay:1-90s 6. Controlled Circuits:4,6,8,10,12 7. Dielectric strength:industrial frequency 3000V
Installation Size
The installation of JKL607 series adopts inserted case,with installation hole on the side.Put the hook of the fastening accessory into the hole,tighten the screw of the accessory and the controller is fixed on the scree. JKL607A overall size:170×110×127mm Holing size:162×102mm(width×height) JKL607B overall size:147×110×127mm Holing size:140×102mm(width×height) JKL607C overall size:120×120×80mm Holing size:113×113mm(width×height) JKL607FA overall size:120×110×127mm Holing size:162×113mm(width×height) JKL607FS overall size:170×110×127mm Holing size:162×102mm(width×height) JKLD607C overall size:120×120×127mm Holing size:113×113mm(width×height)