Type | Designation | Specification | Standard |
HSYV5 | unshielded category 5 solid polyolefin insulated PVC jacketed horizontal pair twisted cable | 4×2×0.5 25×2×0.5 | YD/T 1019 |
HSYY5 | unshielded category 5 solid polyolefin insulated PE jacketed horizontal pair twisted cable | 4×2×0.5 25×2×0.5 | |
HSYVP5 | shielded category 5E solid polyolefin insulated PVC jacketed horizontal pair twisted cable | 4×2×0.5 | |
HSYV5e | unshielded category 5E solid polyolefin insulated PVC jacketed horizontal pair twisted cable | 4×2×0.5 | |
HSYV6 | unshielded category 6 solid polyolefin insulated PE jacketed horizontal pair twisted cable | 4×2×0.5 |
Technical parameters
No. | Electrical property | Unit | 5 | 5e | 6 |
1 | D.C resistance of single conductor max. value | Ω/100m | 9.50 | ||
2 | D.C resistance unbalance max. value | % | 2.5 | ||
3 | operating capacitance max. value | nF/100m | 5.6 | ||
4 | capacitance unbalance between pair and ground max. value | pF/100m | 330 | ||
5 | characteristic impedance | Ω | 100 ± 15 | ||
6 | structural return loss 10 MHz 20 MHz 100 MHz 250 MHz | dB |
23 23 16 — |
28 28 21 — |
30 30 23 23 |
7 | attenuation 10 MHz 20 MHz 100 MHz 250 MHz | dB /100m |
6.5 9.2 22 — |
6.5 9.2 22 — |
5.9 8.4 19.8 32.8 |
8 | near-end cross-talk attenuation 10 MHz 20 MHz 100 MHz 250 MHz | dB /100m |
47 43 32 — |
50 46 35 — |
59 55 44 38 |