Loading Port:SHANGHAI
Payment Terms:TT OR LC
Min Order Qty:50 pc
Supply Capability:5000 pc/month
Product Introduction
Agave-SH-Plus, a brand new single phase hybrid all-in-one BESS, is best for all electric vehicle owners. It fully meets your needs of daily charging at home after get off work. Gain higher battery capacity with better home energy protection.
Pioneer: Lego-style design, easy to install/Decoupling design, easy to maintain
Powerful:Higher weight power density, >95Wh/kg, Up to 26.4kWh
Protectable:PPB level to ensure TWH safety,10 years reliability
Elegant:Easy work in cold and heat, operating between -20°C~60°C, IP65
Energetic:92% DOD, Quick CHG and DCHG, more energy each time
Effortless:Remote update & service by ECOS, always fresh
Parameter
Model | WH-SHC362-13.2kWh/WH-SHC362-16.5kWh WH-SHC362-19.8kWh/WH-SHC362-23.1kWh WH-SHC362-26.4kWh | WH-SHC462-13.2kWh/WH-SHC462-16.5kWh WH-SHC462-19.8kWh/WH-SHC462-23.1kWh WH-SHC462-26.4kWh | WH-SHC502-13.2kWh/WH-SHC502-16.5kWh WH-SHC502-19.8kWh/WH-SHC502-23.1kWh WH-SHC502-26.4kWh | WH-SHC602-13.2kWh/WH-SHC602-16.5kWh WH-SHC602-19.8kWh/WH-SHC602-23.1kWh WH-SHC602-26.4kWh |
Absolute Max Voltage(d.c.V) | 600 | |||
MPPT Voltage Range(d.c.V) | 100-500 | |||
Max.DC Input Power(w) | 4800 | 6200 | 6650 | 8000 |
Start-up Voltage(d.c.V) | 90 | |||
Rated Operating Voltage(d.c.V) | 360 | |||
Max.Input Current(d.c.A) | 12.5/12.5 | |||
Max.inverter backfeed current to array(d.c.A) | 0 | |||
Isc PV(d.c.A) | 18/18 | |||
No.of MPP Trackers | 2 | |||
No.of Strings per MPP Tracker | 1 | |||
Battery | Li-ion | |||
AC Input/Output | ||||
Rated output power(W) | 3600 | 4600 | 5000 | 6000 |
Rated Apparent Power to Grid(VA) | 3600 | 4600 | 5000 | 6000 |
Max.Apparent Power to Grid(VA) | 3600 | 4600 | 5000 | 6000 |
Max.Apparent Power from Grid(VA) | 7200 | 9200 | 10000 | 12000 |
Rated Voltage(a.c.V) | 220/230/240 | |||
Rated Frequency(Hz) | 50/60 | |||
Rated AC Current to Grid(a.c.A) | 16 | 20 | 21.7 | 26.1 |
Rated AC Current from Grid(a.c.A) | 32 | 40 | 43.4 | 52.2 |
Inrush current(a.c.A) | 16 a.c.A (peak), 11.3 us (duration) | |||
Max.output fault current(a.c.A) | 57 (peak), 40 (rms) | |||
AC output Maximum output overcurrent protection(a.c.A) | 40 | |||
AC input power factor | -0.8~+0.8 | |||
AC output power factor | 1 (-0.8...+0.8 adjustable) | |||
THDi | <3%< td=""> | |||
EPS Output | ||||
Max.output power(W) | 3600 | 4600 | 5000 | 6000 |
Rated Apparent Power(VA) | 4320 | 5520 | 6000 | 7200 |
Max.Apparent Power(VA) | 4320 | 5520 | 6000 | 7200 |
Rated Voltage(ac.V) | 220/230/24072 | |||
Nominal Frequency(Hz) | 50/60 (±0.2%) | |||
Max.Output Current(ac.A) | 18.8 | 24 | 26.1 | 31.3 |
Inrush Current(ac.A) | 16 a.c.A (peak), 11.3 us (duration) | |||
Max.output fault current(ac.A) | 57 (peak), 40 (rms) | |||
EPS output Maximum output overcurrent protection(ac.A) | 40 | |||
Switch time(ms) | <10< td=""> | |||
THDv@Linear Load (%) | <2< td=""> | |||
Power Factor | -0.8~+0.8 |
Application Scenairo
Certificates
Our company