Loading Port:Shekou
Payment Terms:TT OR LC
Min Order Qty:10 watt
Supply Capability:10000 watt/month
High Frequency Solar Inverter 2000HF-US-3000HF-US
>Maximum efficiency of 96% >DC switch optional
>High frequency transformer topology
>MTL-String
>Bluetooth technology
2000HF-US 2500HF-US 3000HF-US
Leading - edge Technology
>Maximum efficiency of 96% and wide input voltage range
>DC switch optional
>High frequency transformer topology
>MTL-String
>Bluetooth technology
>Sound control
>Fanless cooling concept
>Easy installation
>High reliability
Input data (DC side) | |||
Model | 2000 HF-US | 2500 HF-US | 3000HF-US |
Specifications | |||
Input data | |||
Max. DC power | 2200W | 2700W | 3200W |
Max. DC voltage | 600V | 600V | 600V |
Start voltage | 150V | 150V | 150V |
DC nominal voltage | 370V | 370V | 370V |
PV voltage range | 100V-600V | 100V-600V | 100V-600V |
MPP voltage range | 195V~480V | 195V~480V | 250V-480V |
Number of MPP trackers/strings per MPP tracker | 1/2 | 1/2 | 1/2 |
Max. input current /per string | 12A/12A | 15A/15A | 15A/15A |
Output (AC) | |||
Nominal AC output power | 2000W@208Vac | ||
2000W@240 Vac | 2500W@208Vac | ||
2500W@240 Vac | 2800W@208Vac | ||
3000W@240Vac | |||
Max. AC power | 2000W | 2500W | 2800W@208Vac |
3000W@240Vac | |||
Nominal output current | 9.6A/8.3A | 12A/10.4A | 13.4A/12.5A |
Max. output current | 10.7A/9.5A | 13.4A/11.8A | 15A/14.2A |
AC nominal voltage; range | 208V/240V; 183V~228V@208Vac | ||
211V~264V@240Vac | 208V/240V; 183V~228V@208Vac | ||
211V~264V@240Vac | 208V/240V; 183V~228V@208Vac | ||
211V~264V@240Vac | |||
AC grid frequency; range | 60Hz; 59.3--60.5Hz | 60Hz; 59.3--60.5Hz | 60Hz; 59.3--60.5Hz |
Phase shift (cosφ) | >0.99 | >0.99 | >0.99 |
THDI | <3%< td=""> | <3%< td=""> | <3%< td=""> |
AC connection | Single phase | Single phase | Single phase |
Efficiency | |||
Max. efficiency | 96% | 96% | 96% |
CEC.effciency | 95% | 95% | 95% |
MPPT efficieny | 99.50% | 99.50% | 99.50% |
Protection devices | |||
DC reverse polarity protection | yes | yes | yes |
AC short - circuit protection | yes | yes | yes |
Ground fault monitoring | yes | yes | yes |
Grid monitoring | yes | yes | yes |
Integrated all - pole sensitive | |||
leakage current monitoring unit | yes | yes | yes |
General Data | |||
Dimensions (W / H / D) in mm | 575/455/160 | 575/455/160 | 575/455/160 |
Weight | 14.6KG | 15.1 KG | 15.9 KG |
Operating temperature | |||
range | –25°C ... +60°C | –25°C...+60 °C | –25°C ... +60°C |
Continuous full output power | |||
temperature range | –25°C…+45°C | –25°C…+45°C | –25°C…+45°C |
Noise emission (typical) | ≤ 25 dB(A) | ≤ 25 dB(A) | ≤ 25 dB(A) |
Altitude | Up to 2000m without power derating | ||
Consumption: operating | |||
(standby) / night | <5W / < 0.5 W | <5W / < 0.5 W | <5 W / < 0.5 W |
Topology | HF transformer | HF transformer | HF transformer |
Cooling concept | No fan | No fan | No fan |
ENCLOSURE | Type 3R | Type 3R | Type 3R |
Installation: Indoors /Outdoors | yes /yes | yes /yes | yes /yes |
Features | |||
DC connection: Terminals | yes | yes | yes |
AC connection: Terminals | yes | yes | yes |
LCD display | yes | yes | yes |
Interfaces: Bluetooth / | |||
RS485/RS232 | opt/yes/yes | opt/yes/yes | opt/yes/yes |
Warranty: 10 years / 15 years | yes /opt | yes /opt | yes /opt |
Certificates and approvals | UI1741,IEEE1547,CSA C22.2 No.107.1, | ||
FCC Part15(Class B) |