Loading Port:China Main Port
Payment Terms:TT OR LC
Min Order Qty:-
Supply Capability:-
1、STANDARDS
GB/T 1179
QB/HYT002
YB/T 5004
GB/T 3428
ASTMB802、 ASTMB803、 ASTMA855、 ASTMA925、 ASTMB957
2、MATERIAL
55#,60#,65#,70#,72A,80#,77B,82B
3、 PACKING
WOOD SPOOL Z2
4、
MECHANICAL PROPERTY OF EXTRA-HIGHTENSILE STEEL WIRE
(mm)Size |
(mm) Tolerance | /Mpa Stress at 1% extension min | /Mpa Tensile strength min | */% Elongation min | mm Wrapping test standard core dia. | Torsion test min / number of turns | |
> | ≤ | ||||||
1.24 | 2.25 | ±0.03 | 1550 | 1870 | 2.0 | 4D | 14 |
2.25 | 2.75 | ±0.04 | 1550 | 1870 | 2.0 | 4D | 14 |
2.75 | 3.00 | ±0.05 | 1550 | 1870 | 2.5 | 5D | 12 |
3.00 | 3.50 | ±0.05 | 1550 | 1870 | 2.5 | 5D | 12 |
3.50 | 4.25 | ±0.06 | 1550 | 1870 | 2.5 | 5D | 10 |
4.25 | 4.75 | ±0.06 | 1510 | 1870 | 2.5 | 5D | 10 |
4.75 | 5.50 | ±0.07 | 1510 | 1870 | 2.5 | 5D | 10 |
Minimun elongation is based on gauge length l0 = 250mm.
Torsion test is based on a standard length of 100 wire diameters.