Loading Port:Tianjin
Payment Terms:TT OR LC
Min Order Qty:25 m.t.
Supply Capability:10000 m.t./month
Model NO.:S350GD+Z S350GD+ZF
Surface Treatment:Galvanized
Technique:Cold Rolled
Standard:ASTM,JIS,GB,AISI,DIN,Bs and Others
Steel Grade:S350gd+Z S350gd+Zf
Export Markets:Global
HS Code:72104900
Production Capacity:10000tons Per Month
Brief Introduction:
Commodity name : Hot Dipped Galvanized Steel Coil
Standard we can provide: AISI ASTM BS DIN GB JIS
Grade : DC51D+Z,DC51D+ZF,St01Z,St02Z,St03Z
Zinc Coating:40g-275g/m2
Size we can provide:
Size Range: CRC substrate Thickness: 0.3-3.0mm
CRC substrate Width: 800-1830mm
HRC substrate Thickness:1.8-2.8mm
HRC substrate Width:900-1500mm
Grade | Chemical composition % | |||||||||
C | Si | Mn | P | S | Alta | Ti | Nb | |||
No more than | No more than | No more than | No more than | No more than | No less than | No more than | No more than | |||
DC51D+Z,DC51D+ZF | 0.1 | --- | 0.5 | 0.035 | 0.035 | --- | --- | --- | ||
(St01Z,St02Z,St03Z) | ||||||||||
Grade | Mechanical properties | plating adhesion | ||||||||
yield strength | tensile strength | n 90 | r 90 | Elongation % | Plating weight(g/m 2 ) | |||||
Mpa | Mpa | No less than | No less than | No less than | Bending diameter | |||||
(a=thickness of slab) | ||||||||||
L 0 =80mm b=20mm | ||||||||||
Normal thickness mm | ||||||||||
≤ 0.7 | >0.7 | ≤ 140/140 | >140/140~ | >175/175 | ||||||
175/175 | ||||||||||
DC51D+Z(St01Z,St02Z,St03 Z), DC51D+ZF | --- | 270~500 | --- | --- | 20 | 22 | 0a | 1a | 2a | |
Exposure Test : | Salt Spray Test : | |||||||||
Environment | GI | Enviroment | GI Average Corrosion | AL-ZN Average Corrosion | ||||||
Average corrosion | ||||||||||
g/m2 /y | μ m/y | g/m2/y | um/y | g/m2/y | um/y | |||||
Tough Marine Climate | 140 | 9.8 | tough Marine Climate | 140 | 9.8 | 16 | 2.2 | |||
Moderate Marine Climate | 18 | 1.3 | Modeerate Marine Climate | 18 | 1.3 | 4 | 0.54 | |||
Industrial Climate | 20 | 1.4 | Industrial Climate | 20 | 1.4 | 4.2 | 0.57 | |||
Countryside Climate | 4 | 0.28 | Countryside Climate | 4 | 0.28 | 1.3 | 0.17 | |||
Plainness of hot dip galvanized substrate A.2.1 For steel sheet with a specified minimum yield strength less than 260MPa, the maximum plainness tolerance should be in conformity with the stipulations of Table A1. | ||||||||||
MPa | Nominal width | Plainness (mm) for the nominal thickness as shown below | ||||||||
Common precise PF.A | High-level precision PF.B | |||||||||
<0.70 | 0.70~<1.60 | 1.60~3.0 | <0.70 | 0.70~<1.60 | 1.60~3.0 | |||||
<260 | <1200 | 10 | 8 | 8 | 5 | 4 | 3 | |||
1200~<1500 | 12 | 10 | 10 | 6 | 5 | 4 | ||||
≥1500 | 17 | 15 | 15 | 8 | 7 | 6 | ||||
For steel sheet and steel strip with a specified minimum yield strength not less than 260MPa but less than 360MPa,and the grades of DC51+Z/Z DD51D+Z /S550GD+Z/ZF), the maximum plainness tolerance should be in conformity with the stipulations of Table A2. Table A2 | ||||||||||
MPa | Nominal width | Plainness (mm) for the nominal thickness as shown below | ||||||||
Common precise PF.A | High-level precision PF.B | |||||||||
<0.70 | 0.70~<1.60 | 1.60~3.0 | <0.70 | 0.70~<1.60 | 1.60~3.0 | |||||
260~<360 | <1200 | 13 | 10 | 10 | 8 | 6 | 5 | |||
1200~<1500 | 15 | 13 | 13 | 9 | 8 | 6 | ||||
≥1500 | 20 | 19 | 19 | 12 | 10 | 9 | ||||
Thickness tolerance for hot dip galvanized substrate | ||||||||||
For steel sheet with a specified minimum yield strength less than 260MPa, the maximum thickness tolerance should be in conformity with the stipulations of Table A6. | ||||||||||
Nominal thickness | Thickness tolerance while the widths are showed as follows | |||||||||
Common precise PT.A | High-level precision PT.B | |||||||||
≤1200 | >1200~1500 | >1500 | ≤1200 | >1200~1500 | >1500 | |||||
0.30~0.40 | ±0.04 | ±0.05 | ±0.06 | ±0.030 | ±0.035 | ±0.040 | ||||
>0.40~0.60 | ±0.04 | ±0.05 | ±0.06 | ±0.035 | ±0.040 | ±0.045 | ||||
>0.60~0.80 | ±0.05 | ±0.06 | ±0.07 | ±0.040 | ±0.045 | ±0.050 | ||||
>0.80~1.00 | ±0.06 | ±0.07 | ±0.08 | ±0.045 | ±0.050 | ±0.060 | ||||
>1.00~1.20 | ±0.07 | ±0.08 | ±0.09 | ±0.050 | ±0.060 | ±0.070 | ||||
>1.20~1.60 | ±0.10 | ±0.11 | ±0.12 | ±0.060 | ±0.070 | ±0.080 | ||||
>1.60~2.00 | ±0.12 | ±0.13 | ±0.14 | ±0.070 | ±0.080 | ±0.090 | ||||
>2.00~2.50 | ±0.14 | ±0.15 | ±0.16 | ±0.090 | ±0.100 | ±0.110 | ||||
>2.50~3.00 | ±0.17 | ±0.17 | ±0.18 | ±0.110 | ±0.120 | ±0.130 | ||||
For steel sheet and steel strip with a specified minimum yield strength not less than 260MPa but less than 360MPa, the thickness tolerance should be in conformity with the stipulations of Table A7. | ||||||||||
Nominal thickness | Thickness tolerance while the widths are showed as follows | |||||||||
Common precise PT.A | High-level precision PT.B | |||||||||
≤1200 | >1200~1500 | >1500 | ≤1200 | >1200~1500 | >1500 | |||||
0.30~0.40 | ±0.05 | ±0.06 | ±0.07 | ±0.035 | ±0.040 | ±0.045 | ||||
>0.40~0.60 | ±0.05 | ±0.06 | ±0.07 | ±0.040 | ±0.045 | ±0.050 | ||||
>0.60~0.80 | ±0.06 | ±0.07 | ±0.08 | ±0.045 | ±0.050 | ±0.060 | ||||
>0.80~1.00 | ±0.07 | ±0.08 | ±0.09 | ±0.050 | ±0.060 | ±0.070 | ||||
>1.00~1.20 | ±0.08 | ±0.09 | ±0.11 | ±0.060 | ±0.070 | ±0.080 | ||||
>1.20~1.60 | ±0.11 | ±0.13 | ±0.14 | ±0.070 | ±0.080 | ±0.090 | ||||
>1.60~2.00 | ±0.14 | ±0.15 | ±0.16 | ±0.080 | ±0.090 | ±0.110 | ||||
>2.00~2.50 | ±0.16 | ±0.17 | ±0.18 | ±0.110 | ±0.120 | ±0.130 | ||||
>2.50~3.00 | ±0.19 | ±0.20 | ±0.20 | ±0.130 | ±0.140 | ±0.150 | ||||
For steel sheet and steel strip with a specified minimum yield strength not less than 360MPa, but less than or equal to 420 MPa, the thickness tolerance should be in conformity with the stipulations of Table A8. | ||||||||||
Nominal thickness | Thickness tolerance while the widths are showed as follows | |||||||||
Common precise PT.A | High-level precision PT.B | |||||||||
≤1200 | >1200~1500 | >1500 | ≤1200 | >1200~1500 | >1500 | |||||
0.30~0.40 | ±0.05 | ±0.06 | ±0.07 | ±0.040 | ±0.045 | ±0.050 | ||||
>0.40~0.60 | ±0.06 | ±0.07 | ±0.08 | ±0.045 | ±0.050 | ±0.060 | ||||
>0.60~0.80 | ±0.07 | ±0.08 | ±0.09 | ±0.050 | ±0.060 | ±0.070 | ||||
>0.80~1.00 | ±0.08 | ±0.09 | ±0.11 | ±0.060 | ±0.070 | ±0.080 | ||||
>1.00~1.20 | ±0.10 | ±0.11 | ±0.12 | ±0.070 | ±0.080 | ±0.090 | ||||
>1.20~1.60 | ±0.13 | ±0.14 | ±0.16 | ±0.080 | ±0.090 | ±0.110 | ||||
>1.60~2.00 | ±0.16 | ±0.17 | ±0.19 | ±0.090 | ±0.110 | ±0.120 | ||||
>2.00~2.50 | ±0.18 | ±0.20 | ±0.21 | ±0.120 | ±0.130 | ±0.140 | ||||
>2.50~3.00 | ±0.22 | ±0.22 | ±0.23 | ±0.140 | ±0.150 | ±0.160 | ||||
For steel sheet and steel strip with a specified minimum yield strength not less than 420MPa, but less than or equal to 900 MPa, the thickness tolerance should be in conformity with the stipulations of Table A9. | ||||||||||
Nominal thickness | Thickness tolerance while the widths are showed as follows | |||||||||
Common precise PT.A | High-level precision PT.B | |||||||||
≤1200 | >1200~1500 | >1500 | ≤1200 | >1200~1500 | >1500 | |||||
0.30~0.40 | ±0.06 | ±0.07 | ±0.08 | ±0.045 | ±0.050 | ±0.060 | ||||
>0.40~0.60 | ±0.06 | ±0.08 | ±0.09 | ±0.050 | ±0.060 | ±0.070 | ||||
>0.60~0.80 | ±0.07 | ±0.09 | ±0.11 | ±0.060 | ±0.070 | ±0.080 | ||||
>0.80~1.00 | ±0.09 | ±0.11 | ±0.12 | ±0.070 | ±0.080 | ±0.090 | ||||
>1.00~1.20 | ±0.11 | ±0.13 | ±0.14 | ±0.080 | ±0.090 | ±0.110 | ||||
>1.20~1.60 | ±0.15 | ±0.16 | ±0.18 | ±0.090 | ±0.110 | ±0.120 | ||||
>1.60~2.00 | ±0.18 | ±0.19 | ±0.21 | ±0.110 | ±0.120 | ±0.140 | ||||
>2.00~2.50 | ±0.21 | ±0.22 | ±0.24 | ±0.140 | ±0.150 | ±0.170 | ||||
>2.50~3.00 | ±0.24 | ±0.25 | ±0.26 | ±0.170 | ±0.180 | ±0.190 | ||||
Width tolerance | ||||||||||
Nominal width | Width tolerance | Width | ||||||||
FAQ
1.What's your MOQ?
25MT, it is for one container.
2.Do you have QC teams?
Yeah, sure, our QC team is very important, they will keep the quality control for our products.
3. What's your normal delivery time?
Our delivery time about 10-20days for standard sizes, if you have other requirements like hardness and width ,it is about 20-40days. But don't worry ,we also try our best for the delivery time ,because time longer and our cost is higher.
4.Are the products tested before shipping?
Yes, all of our PPGI and GI was qualified before shipping. We test every batch every day.