Loading Port:China main port
Payment Terms:TT OR LC
Min Order Qty:500 m
Supply Capability:50000 m/month
ISO9001:2008, ISO14001, APIQ1, CE
2.Rated voltage:8.7/10kV
1. Executive Standard
MT818.13-2009 (Chinese) Cables for coal mine part 13: Cross-linked polyethylene insulation power cables for coal mine rated voltage up to and including 8.7/10kV.
Produt Model ,Name and Use shown in Table 1
Model | Name | Use |
MYJV22 | XLPE insulator PVC sheathed power cable for coal mining | Mainly used for laying indoors and in the tunnel and pipelines. The cable can not bear greater external machanical forces |
MYJV22 | XLPE insulator steel tape armoured PVC sheathed power cable for coal mining | Mainly used for laying indoors and underground, and in the tunnel and pipelines. The cable can not bear greater machanical tension, but certain machanical pressure |
MYJV32 | XLPE insulator thin steel wire armoured PVC sheathed power cable for coal mining | Mainly used for laying indoors and underground, and in the tunnel and pipelines. The cable can bear greater machanical tension and certain machanical pressure |
MYJV42 | XLPE insulator thick steel wire armoured PVC sheathed power cable for coal mining | Mainly used for laying indoors and underground, and in the tunnel and pipelines. The cable can bear certain machanical pressure and greater machanical tension |
Product Insulation Thickness shown in Table
Model | Nominal section(mm2) | Conductor DC resistance at 20°C(Ω/km) |
No Tin Plating | ||
MVV MVV22 | 1.5 | 12.1 |
2.5 | 7.41 | |
4 | 4.61 | |
6 | 3.08 | |
10 | 1.83 | |
16 | 1.15 | |
25 | 0.727 | |
35 | 0.524 | |
50 | 0.387 | |
70 | 0.268 | |
95 | 0.193 | |
120 | 0.153 | |
150 | 0.124 | |
185 | 0.0991 | |
240 | 0.0754 | |
300 | 0.0601 |
2. Product Working Conditions
(1) The Maximum rated working temperature of the cable conductor is 90 °C.
(2) The Maximum temperature of the cable conductor is 250°C, when it is short-circuited( the longest duration time is 5s)
(3) The Minimum bending radius of the cable is 15 times of the diameter.
3. Packaging
(1) The cable drums for delivery should comply with the requirements of JB/T 8137.
(2) The coils of cable should be neatly wound on to the cable drums for delivery. The cable end should be tightly encapsulated.
(3) Only the cable of the same model and specifications is allowed to be wound on to one cable drum.
(4) The cables provided in rolls or bunches should be packaged in a proper way. The weight of every roll should not be more than 80kg.
(5) The cable drum should be attached with the packaging signs prescribed in 8.4 and indicate its right rotation direction.
4. Transport and Storage
The cables should adjust to all the transport means including the water, land and air transport. In the process of transport and storage, great attention should be paid to:
(1) Preventing moisture from entering into the cable.
(2) Preventing severe bending and other mechanical damages.
(3) Preventing high temperature and exposure to the sunlight.