Fire Rated Cable Mica Fire Resistant Cable Can Pass IEC60331 BS6387C.W.Z AS/NZS3013 WS52FIRE TEST

Loading Port:China main port

Payment Terms:TT or LC

Min Order Qty:1000 m

Supply Capability:20000 m/month

Product Description:

Fire Rated Cable Mica Fire Resistant Cable

 

1. Construction (CAT5E/CAT6 UTP):

 

Inner conductor

material

Copper Clad Aluminium

diameter

0.51

up

+0.005

down

-0.005

dielectric

material

HDPE

diameter

0.91±0.02 mm

sheath

thickness

0.55±0.05mm

diameter

5.3±0.1  mm

surface

Clean.frap,satiation

material

PVC(complies RoHS)

color

to customer requirement

printing

Letter height

3.0±0.3mm

color

Black

space

1m

PE color

Blue ,White/Blue

Orange,White/Orange

Green,White/Green

Brown,White/Brown

 

 

 


 

 


 


 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. Description

Conductor: Solid bare copper / AWG 23/24/26/28
Conductor Dia(mm): 0.40-0.57
Insulation: PE
Average thickness ( +/-0.03mm): 0.3mm
Min point thickness: 0.28mm
Cross:
Insulation Dia ( +/-0.03mm): 1.10mm
Jacket: PVC or LSZH
Average thickness: 0.55
Min point thickness: 0.53
Outer Dia( +/-1.0mm) 6.3
Rip cord: YES

 

Rated Temperature: -20° C ~ + 75° C 
Core color:
Pair 1: Blue - white/blue
Pair 2: Orange - white/orange
Pair 3: Green - white/orange
Pair 4: Brown - white/brown

3. Electrical Performance (At 100MHz)
1.0-100.0MHz Impendance(ohms) 100+/-15
1.0-100.0MHz Impendance delay screw(ns/100m) <45
Pair to Ground Capacitance Unbalance (PF/100m) 330Max
Conductor DC resistance 20%(ohms/km) <93.8
Resistance Unbalance(%): 5
Spark Test 850 V AC
Dielectric Strength 2500 V DC / 3 seconds
Insulation Resistance Test Min. 150 MΩ /Km
Conductor Resistance Max. 9.38Ω /100m at 20
Resistance Unbalance Max. 5%
Capacitance Unbalance Max. 330 pF/100m
Mutual Capacitance Max. 5600 pF/100m

Test object: Jacket
Test Material: PVC, PE, LSZH
Before Tensile strength(Mpa): >=13.8
Aging Elongation ((%): >=100
Aging condition(C xhrs): 100x240
After Tensile strength(Mpa): >=85% of unaged
Aging Elongation(%): >=50% of n

 

 4.Application 
Mainly Used In The Building Correspondence Synthesis Wiring System The Work Area Correspondence Leading-out Terminal and between the Connection Distribution Frame Wiring, As Well As the Housing Synthesis Wiring System's User Correspondence Leading-out Terminal Arrives at Place of Exile between Coils' wiring. 

5 . The Datasheet of  Cat5e Lan Cable

Conductor

Thick.of insulation

mm

Nominal O.D.

mm

Weight

kgs/305m box

24AWG

0.91±0.005

5.0±0.2

9.0

Max. Conductor Resistance: 9.2Ω/100m

Min. Insulation Elongation: 300%

Max. Resistance Unbalance: 2.4%

Min. Propagation Velocity: 0.62C m/s

Min. Conductor Elongation: 20%

Characteristic Impedance: 100±15Ω

Min. Insulation Resistance: 7000MΩ/km

Frequency

 

(Mhz)

Insertion Loss

(Soild)

Max,dB/100m

Next

(Worst pair to pair)

Min.dB

PSNEXT

Power Sum NEXT

Min.dB

ELFEXT

Power Sum ELFEXT

Min.dB/100m

PSLFEXT

Power Sum ELFEXT

Min.dB/100m

Return Loss

 

Min.dB

1

2

65.3

62.3

20

64

61

10

6.5

50.3

47.3

25

44

41

25

10.4

44.3

41,3

24.3

35.8

33

31.25

11.7

42.9

39.9

23.6

34.1

31.1

62.5

17

38.4

35.4

21.5

28.1

25.1

100

22

35.3

32.3

20.1

24

21

 6.Picture

Fire Rated Cable Mica Fire Resistant Cable Can Pass IEC60331 BS6387C.W.Z AS/NZS3013 WS52FIRE TEST