Features of Ethernet Switch Series
Provides flexibility of 8 Ethernet ports that configure in combinations of copper and fiber optic interfaces
Redundant power inputs with Terminal Block or DC Jack
20°C to 60°C (-4°F to 140°F) and is tested for functional operation @ -30°C to 70°C (-22°F to 158°F)
10/100Mbps-Full/Half-duplex, Auto-Negotiation, Auto-MDI/MDIX
Complies with IEC61000-6-2 EMC Generic standard immunity for Industrial environment
Alarms for power failure by relay output
Standards:
IEEE802.3 10BASE-T, IEEE802.3u 100BASE-TX/100BASE-FX, IEEE802.3x
Forward and Filtering Rate:
14,880pps for 10Mbps 148,810pps for 100Mbps
Packet Buffer Memory:
768K bits
Processing Type:
Store-and-Forward Half-duplex back-pressure and IEEE802.3x full-duplex flow control
Address Table Size:
2048 MAC addresses
Power Input:
Input Voltage: 12 to 30VDC (Terminal Block); 12VDC (DC Jack)
Power Consumption:
4.8W Max. 0.38A @ 12VDC, 0.2A @ 24VDC
Reverse Polarity Protection:
Present
Mechanical Casing:
Aluminum case IP30
Dimensions:
50mm (W) x 125mm (D) x 135mm (H) (1.97" (W) x 4.92" (D) x 5.31" (H))
Weight:
0.8Kg (1.76lbs.)
| Environment Operating Temperature:
-20°C to 60°C (-4°F to 140°F) Tested @ -30°C to 70°C (-22°F to 158°F)
Storage Temperature:
-40°C to 85°C (-40°F to 185°F)
Ambient Relative Humidity:
5% to 95% (non-condensing)
Regulatory Approvals ISO:
Manufactured in an ISO9001 facility
Safety:
UL60950-1
EMI:
FCC Part 15, Class A EN61000-6-3 EN55022 EN61000-3-2 EN61000-3-3
EMS:
EN61000-6-2 EN61000-4-2 (ESD Standards) Contact: + / - 4KV; Criteria B Air: + / - 8KV; Criteria B EN61000-4-3 (Radiated RFI Standards) 10V/m, 80 to 1000MHz; 80% AM Criteria A 3V/m, 1400 to 2000MHz; 80% AM Criteria A 1V/m, 2000 to 2700MHz; 80% AM Criteria A EN61000-4-4 (Burst Standards) Signal Ports: + / - 4KV; Criteria B D.C. Power Ports: + / - 4KV; Criteria B EN61000-4-5 (Surge Standards) Signal Ports: + / - 1KV; Line-to-Line; Criteria B D.C. Power Ports: + / - 0.5KV; Line-to-earth; Criteria B EN61000-4-6 (Induced RFI Standards) Signal Ports: 10Vrms @ 0.15~80MHz; 80% AM Criteria A D.C. Power Ports: 10Vrms @ 0.15~80MHz; 80% AM Criteria A EN61000-4-8 (Magnetic Field Standards) 30A/m @ 50, 60Hz; Criteria A |