Ethernet Switch Series

Loading Port:China Main Port

Payment Terms:TT or LC

Min Order Qty:5 Boxes pc

Supply Capability:1000 Boxes per Month pc/month

Product Description:

 

Features of Ethernet Switch Series

 

Provides flexibility of 8 Ethernet ports that configure in combinations of copper and fiber optic interfaces

 

 Redundant power inputs with Terminal Block or DC Jack

 

 20°C to 60°C (-4°F to 140°F) and is tested for functional operation @ -30°C to 70°C (-22°F to 158°F)

 

10/100Mbps-Full/Half-duplex, Auto-Negotiation, Auto-MDI/MDIX

 

Complies with IEC61000-6-2 EMC Generic standard immunity for Industrial environment

 

Alarms for power failure by relay output

 

Standards:

 

IEEE802.3 10BASE-T, IEEE802.3u 100BASE-TX/100BASE-FX, IEEE802.3x

 

Forward and Filtering Rate:

 

14,880pps for 10Mbps

148,810pps for 100Mbps

 

Packet Buffer Memory:

 

768K bits

 

Processing Type:

 

Store-and-Forward

Half-duplex back-pressure and IEEE802.3x full-duplex flow control

 

Address Table Size:

 

2048 MAC addresses

 

Power

Input:

 

Input Voltage: 12 to 30VDC (Terminal Block); 12VDC (DC Jack)

 

Power Consumption:

 

4.8W Max. 0.38A @ 12VDC, 0.2A @ 24VDC

 

Reverse Polarity Protection:

 

Present

 

Mechanical

Casing:

 

Aluminum case

IP30

 

Dimensions:

 

50mm (W) x 125mm (D) x 135mm (H)

(1.97" (W) x 4.92" (D) x 5.31" (H))

 

Weight:

 

0.8Kg (1.76lbs.)

 

Environment

Operating Temperature:

 

-20°C to 60°C (-4°F to 140°F)

Tested @ -30°C to 70°C (-22°F to 158°F)

 

Storage Temperature:

 

-40°C to 85°C (-40°F to 185°F)

 

Ambient Relative Humidity:

 

5% to 95% (non-condensing)

 

Regulatory Approvals

ISO:

 

Manufactured in an ISO9001 facility

 

Safety:

 

UL60950-1

 

EMI:

 

FCC Part 15, Class A

EN61000-6-3

EN55022

EN61000-3-2

EN61000-3-3

 

EMS:

 

EN61000-6-2

EN61000-4-2 (ESD Standards)

Contact: + / - 4KV; Criteria B

Air: + / - 8KV; Criteria B

EN61000-4-3 (Radiated RFI Standards)

10V/m, 80 to 1000MHz; 80% AM Criteria A

3V/m, 1400 to 2000MHz; 80% AM Criteria A

1V/m, 2000 to 2700MHz; 80% AM Criteria A

EN61000-4-4 (Burst Standards)

Signal Ports: + / - 4KV; Criteria B

D.C. Power Ports: + / - 4KV; Criteria B

EN61000-4-5 (Surge Standards)

Signal Ports: + / - 1KV; Line-to-Line; Criteria B

D.C. Power Ports: + / - 0.5KV; Line-to-earth; Criteria B

EN61000-4-6 (Induced RFI Standards)

Signal Ports: 10Vrms @ 0.15~80MHz; 80% AM Criteria A

D.C. Power Ports: 10Vrms @ 0.15~80MHz; 80% AM Criteria A

EN61000-4-8 (Magnetic Field Standards)

30A/m @ 50, 60Hz; Criteria A