Etaseco,Horizontal / vertical, seal-less volute casing pump

Loading Port:Shanghai

Payment Terms:TT OR LC

Min Order Qty:1 unit

Supply Capability:10 unit/month

Product Description:

Design
Horizontal / vertical, seal-less volute casing pump in back pull-out design with fully enclosed canned motor, low noise emission, with radial impeller, singlestage, single-entry, pump casing connecting dimensions to EN 733.                                              
Applications
Handling of aggressive, flammable, toxic, volatile, or valuable liquids in the chemical and petrochemical industry, in environmental engineering and the general industry.

Overview of technical data

Type of impeller                                                                         Multi- vane impeller;Closed;Closed / Radial;Radial                    
Type of installation                                                                         Close- coupled                    
Maximum drive rating                                                                         18                         kW                    
Impeller material (EN standard)                                                                         JL1040; JS1025                    
Type of bearing                                                                         Plain bearings                    
Drive frequency                                                                         50 Hz / 60 Hz                    
Maximum speed of rotation                                                                         3. 500                         1/min                    
Maximum flow rate                                                                         250                         m³/h                    
Maximum discharge-side pressure                                                                         16                         bar                    
Casing material (EN standard)                                                                         JS1025; JL1040                    
No. of impeller entries                                                                         Single entry                    
Casing material                                                                         Cast iron; Nodular cast iron                    
Minimum flow rate                                                                         3                         m³/h                    
Suction characteristics                                                                         Non- priming                    
Drive voltage                                                                         Low voltage                    
eClass assignment                                                                         36410100; 36410101;36410000                    
Pull-out design                                                                         Yes                    
Pump set location                                                                         Dry installed                    
Max. permissible fluid temperature                                                                         140                         °C                    
Main applications                                                                         Industry and process engineering                    
Type of installation                                                                         Stationary                    
Type of casing                                                                         Volute casing                    
Type of connection                                                                         Flange                    
Type of lubrication                                                                         Oil / Product lubrication                    
Type of drive                                                                         Electric motor                    
Installation position                                                                         Horizontal or vertical                    
Shaft material (EN standard)                                                                         1. 4021                    
Type of coupling                                                                         Direct                    
Shaft seal type                                                                         Canned motor pump                    
Drive                                                                         IEC standardized motor                    
Maximum head                                                                         100, 00                         m                    
Maximum rated pressure (discharge)                                                                         PN 16                    
Minimum head                                                                         9, 00                         m                    
Nozzle position                                                                         End suction                    
Casing partition                                                                         Radially split                    
Connection to power supply                                                                         220/ 400/690 V, 3~