Etanorm,Horizontal, long-coupled, single-stage volute casing pump

Loading Port:Shanghai

Payment Terms:TT OR LC

Min Order Qty:1 unit

Supply Capability:10 unit/month

Product Description:

Design
Horizontal, long-coupled, single-stage volute casing pump with ratings and main dimensions to EN 733 in back pull-out design, with replaceable shaft sleeves / shaft protecting sleeves and casing wear rings. Design to ATEX.                                                
Applications
Spray irrigation, irrigation, drainage, district heating, water supply  systems, heating and air-conditioning systems, condensate transport,  swimming pools, fire-fighting systems, handling of hot water, cooling   water, fire-fighting water, oil, brine, drinking water, brackish water, service water, etc.

Overview of technical data

Type of impeller                                                                         Closed / Radial                    
Type of installation                                                                         Long- coupled                    
Impeller material (EN standard)                                                                         1. 4408 / A743 GR CF8 M;CC480K-GS / B30 C90700;JL1040 / A 48 CL 35B                    
Type of bearing                                                                         Ball bearings                    
Drive frequency                                                                         50 Hz / 60 Hz                    
Maximum speed of rotation                                                                         3. 500                         1/min                    
Maximum flow rate                                                                         740                         m³/h                    
Maximum discharge-side pressure                                                                         16                         bar                    
Suitable for drinking water                                                                         Yes                    
Casing material (EN standard)                                                                         1. 4408 / A743 GR CF8 M;CC480K-GS / B30 C90700;JL1040 / A48CL35B;JS1030 / A536 GR 60-40-18                    
No. of impeller entries                                                                         Single entry                    
Casing material                                                                         Cast iron; Stainless steel;Nodular cast iron;Bronze                    
Minimum flow rate                                                                         1, 50                         m³/h                    
Suction characteristics                                                                         Non- priming                    
Drive voltage                                                                         Low voltage                    
eClass assignment                                                                         36410000; 36410100;36410101                    
Pull-out design                                                                         Yes                    
Pump set location                                                                         Dry installed                    
Explosion protection                                                                         IP 55                    
Max. permissible fluid temperature                                                                         140                         °C                    
UNSPSC classification                                                                         4015150300                    
Main applications                                                                         Industry and process engineering; Water;Energy;Building services                    
Type of installation                                                                         Stationary                    
Type of casing                                                                         Volute casing                    
Type of connection                                                                         Flange                    
Type of lubrication                                                                         Grease / Oil lubrication                    
Type of drive                                                                         Electric motor                    
Installation position                                                                         Horizontal                    
Shaft material (EN standard)                                                                         1. 4571;C45+N                    
Type of coupling                                                                         Direct                    
Shaft seal type                                                                         Mechanical seal; Gland packing                    
Maximum head                                                                         160, 00                         m                    
Maximum rated pressure (discharge)                                                                         PN 16                    
Minimum head                                                                         2, 00                         m                    
Standard                                                                         EN; EN / ANSI                    
Nozzle position                                                                         End suction                    
Casing partition                                                                         Radially split                    
Guaranteed to be silicon-free                                                                         Yes