EPR Fire Resistant Marine Cable

Loading Port:China main port

Payment Terms:TT OR LC

Min Order Qty:1000 m

Supply Capability:20000 m/month

Product Description:

Marine Cable

EPR Fire resistant Marine Cable application

This cable is used on ships,petrol platforms and offshore buildings for emergency power,light and control system.

EPR Fire resistant Marine Cable standards

IEC 60092-350
IEC 60092-353
IEC 60332-1-2
IEC 60332-3-22
IEC 67054-1-2
IEC 61034

EPR Fire resistant Marine Cable service condition

1.Rated Voltage:0.6/1(1.2)kV,1.8/3 kV

2.Long term allowable working temperature:90°C

3.Finished Cable can withstand AC 3.5kv/5 minutes without puncture.

4.Cable bending radius

Cable StructureCable Outer DiameterMinimum Bending Radius
Metal Braided Armored6D
Non ArmoredD≤254D
D>256D

EPR Fire resistant Marine Cable Model

ModelCombustionName
CEPFSC/NC/NSCEPR insulated LSZH SHF1 sheath flame retardant marine power cable
CEPF80SC/NC/NSC

EPR insulated LSZH SHF1 inner sheath bare copper wire braid armored flame retardant marine power cable

CEPF85SC/NC/NSCEPR insulated LSZH SHF1 inner sheath bare copper wire braid armored SHF1 outer sheath flame retardant marine power cable
CEPF90SC/NC/NSCEPR insulated LSZH SHF1 inner sheath bare steel wire braid armored flame retardant marine power cable
CEPF95SC/NC/NSCEPR insulated LSZH SHF1 inner sheath bare steel wire braid armored SHF1 outer sheath flame retardant marine power cable
CEPFRSC/NC/NSCEPR insulated LSZH SHF1 sheath flame retardant marine power flexible cable
CEPJSC/NC/NSCEPR insulated LSZH SHF2 sheath flame retardant marine power cable
CEPJ80SC/NC/NSCEPR insulated LSZH SHF2 inner sheath bare copper wire braid armored flame retardant marine power cable
CEPJ85SC/NC/NSCEPR insulated LSZH SHF2 inner sheath bare copper wire braid armored SHF1 outer sheath flame retardant marine power cable
CEPJ90SC/NC/NSCEPR insulated LSZH SHF2 inner sheath bare steel wire braid armored flame retardant marine power cable
CEPJ95SC/NC/NSCEPR insulated LSZH SHF2 inner sheath bare steel wire braid armored SHF1 outer sheath flame retardant marine power cable
CEPJRSC/NC/NSCEPR insulated LSZH SHF2 sheath flame retardant marine power flexible cable

EPR Fire resistant Marine Cable Specification

Model

Core

Nominal Cross-section Area

mm2

CEPF/SC/NC/NSC,CEPF80/SC/NC/NSC,CEPF86/SC/NC/NSC

CEPF90/SC/NC/NSC,CEPF96/SC/NC/NSC,CEPFR/SC/NC/NSC

CEPJ/SC/NC/NSC,CEPJ80/SC/NC/NSC,CEPJ85/SC/NC/NSC

CEPJ90/SC/NC/NSC,CEPJ95/SC/NC/NSC,CEPJR/SC/NC/NSC,

1

1~300

2

1~120

3

1~185

4~37

1~2.5

Note:Unlisted cable model can be produced as customer request.

EPR Fire resistant Marine Cable Product Code

Code

Insulation

Code

Inner sheath

Code

Armor

Code

outer Sheath

E

J

V

X

EPR

XLPE(Low Pressure)

PVC

NR-SBR

V

F

H

PF

PJ

PVC

CR

CSP

SHF1

SHF2

0

8

9

 

Copper Wire Braid

Steel Wire Braid

0

2

5

6

PVC

SHF2

SHF1

Code

Definition

Code

Definition

D

S

N

Single Burning

Bundled Burning

Fire resistant

A

B

C

Smoke,Acid,poisonous

Low smoke,Low Acid,Low Poisonous

Halogen Free,Low Smoke,Low Poisonous

Soft------R

Shield ------P

Waterproof------M

EPR Fire resistant marine cable construction

1.Copper conductor C10200 Cu-OF

2.Fire resistant layer Mica tape

3.EPR insulation

4.Filler(if necessary)

5.Tape

6.Inner sheath(PCP/PVC)

7.Metal wire braid(Copper wire braid or Gavalanized steel wire braid)

8.Outer Sheath(PVC)