Loading Port:China main port
Payment Terms:TT OR LC
Min Order Qty:1000 m
Supply Capability:20000 m/month
Marine Cable
EPR Fire resistant Marine Cable application
This cable is used on ships,petrol platforms and offshore buildings for emergency power,light and control system.
EPR Fire resistant Marine Cable standards
IEC 60092-350
IEC 60092-353
IEC 60332-1-2
IEC 60332-3-22
IEC 67054-1-2
IEC 61034
EPR Fire resistant Marine Cable service condition
1.Rated Voltage:0.6/1(1.2)kV,1.8/3 kV
2.Long term allowable working temperature:90°C
3.Finished Cable can withstand AC 3.5kv/5 minutes without puncture.
4.Cable bending radius
Cable Structure | Cable Outer Diameter | Minimum Bending Radius |
Metal Braided Armored | 6D | |
Non Armored | D≤25 | 4D |
D>25 | 6D |
EPR Fire resistant Marine Cable Model
Model | Combustion | Name |
CEPF | SC/NC/NSC | EPR insulated LSZH SHF1 sheath flame retardant marine power cable |
CEPF80 | SC/NC/NSC | EPR insulated LSZH SHF1 inner sheath bare copper wire braid armored flame retardant marine power cable |
CEPF85 | SC/NC/NSC | EPR insulated LSZH SHF1 inner sheath bare copper wire braid armored SHF1 outer sheath flame retardant marine power cable |
CEPF90 | SC/NC/NSC | EPR insulated LSZH SHF1 inner sheath bare steel wire braid armored flame retardant marine power cable |
CEPF95 | SC/NC/NSC | EPR insulated LSZH SHF1 inner sheath bare steel wire braid armored SHF1 outer sheath flame retardant marine power cable |
CEPFR | SC/NC/NSC | EPR insulated LSZH SHF1 sheath flame retardant marine power flexible cable |
CEPJ | SC/NC/NSC | EPR insulated LSZH SHF2 sheath flame retardant marine power cable |
CEPJ80 | SC/NC/NSC | EPR insulated LSZH SHF2 inner sheath bare copper wire braid armored flame retardant marine power cable |
CEPJ85 | SC/NC/NSC | EPR insulated LSZH SHF2 inner sheath bare copper wire braid armored SHF1 outer sheath flame retardant marine power cable |
CEPJ90 | SC/NC/NSC | EPR insulated LSZH SHF2 inner sheath bare steel wire braid armored flame retardant marine power cable |
CEPJ95 | SC/NC/NSC | EPR insulated LSZH SHF2 inner sheath bare steel wire braid armored SHF1 outer sheath flame retardant marine power cable |
CEPJR | SC/NC/NSC | EPR insulated LSZH SHF2 sheath flame retardant marine power flexible cable |
EPR Fire resistant Marine Cable Specification
Model | Core | Nominal Cross-section Area mm2 |
CEPF/SC/NC/NSC,CEPF80/SC/NC/NSC,CEPF86/SC/NC/NSC CEPF90/SC/NC/NSC,CEPF96/SC/NC/NSC,CEPFR/SC/NC/NSC CEPJ/SC/NC/NSC,CEPJ80/SC/NC/NSC,CEPJ85/SC/NC/NSC CEPJ90/SC/NC/NSC,CEPJ95/SC/NC/NSC,CEPJR/SC/NC/NSC, | 1 | 1~300 |
2 | 1~120 | |
3 | 1~185 | |
4~37 | 1~2.5 | |
Note:Unlisted cable model can be produced as customer request. |
EPR Fire resistant Marine Cable Product Code
Code | Insulation | Code | Inner sheath | Code | Armor | Code | outer Sheath |
E J V X | EPR XLPE(Low Pressure) PVC NR-SBR | V F H PF PJ | PVC CR CSP SHF1 SHF2 | 0 8 9
| — Copper Wire Braid Steel Wire Braid | 0 2 5 6 | — PVC SHF2 SHF1 |
Code | Definition | Code | Definition |
D S N | Single Burning Bundled Burning Fire resistant | A B C | Smoke,Acid,poisonous Low smoke,Low Acid,Low Poisonous Halogen Free,Low Smoke,Low Poisonous |
Soft------R
Shield ------P
Waterproof------M
EPR Fire resistant marine cable construction
1.Copper conductor C10200 Cu-OF
2.Fire resistant layer Mica tape
3.EPR insulation
4.Filler(if necessary)
5.Tape
6.Inner sheath(PCP/PVC)
7.Metal wire braid(Copper wire braid or Gavalanized steel wire braid)
8.Outer Sheath(PVC)