Loading Port:Shanghai
Payment Terms:TT OR LC
Min Order Qty:20 set
Supply Capability:200 set/month
1. Structure of Eccentric Heat Pipe Vacuum Tube Solar Collector Model SC-HE
This product is composed of the following parts:
1 Manifold
2 Collector Joint
3 All aluminum alloy shell and frame
4 All Glass Vacuum Tube , with reflection mirror sealed in
5 Tube Holder
6 Wind Feet
2. Main Features of Eccentric Heat Pipe Vacuum Tube Solar Collector Model SC-HE
Double ratio of light concentration, the temperature inside the tube is 30% higher than the normal tubes.
Superconducting copper heat pipe and large heat transfer area of the condensing end with high power of heat transfer and fast speed of start working.
The reflection mirror can avoid the effects from external environment and ensure that the mirror reflectivity is not reduced.
All aluminum alloy shell and frame with oxidation and coating anti-corrosion surface, corrosion resistance, easy to be installed.
The thermal insulation layer with rock wool/glass wool that can resistant high temperature, compression molding, high density, small coefficient of thermal conductivity.
Copper pipe with high purity and quality, pressure and corrosion resistance, can stand 1MPa.The gravity heat pipe transfers heat by one way, high heat collecting efficiency but low heat lost.
3. Eccentric Heat Pipe Vacuum Tube Solar Collector Model SC-HE Images
4. Eccentric Heat Pipe Vacuum Tube Solar Collector Model SC-HE Specifications
Model | SC-HCM-10 | SC-HCM-15 | SC-HCM-18 | SC-HCM-20 | SC-HCM-24 | SC-HCM-25 | SC-HCM-30 |
Tube Qty(pcs) | 10 | 15 | 18 | 20 | 24 | 25 | 30 |
Tube Pitch(㎜) | 90 | 90 | 90 | 90 | 90 | 90 | 90 |
Tube Diameter/ Length(㎜) | φ70/2000 | φ70/2000 | φ70/2000 | φ70/2000 | φ70/2000 | φ70/2000 | φ70/2000 |
Vacuum Tube Material | high borosilicate glass 3.3 | high borosilicate glass 3.3 | high borosilicate glass 3.3 | high borosilicate glass 3.3 | high borosilicate glass 3.3 | high borosilicate glass 3.3 | high borosilicate glass 3.3 |
Thickness of Inner Tube/Outer Tube(㎜) | 1.6/2.0 | 1.6/2.0 | 1.6/2.0 | 1.6/2.0 | 1.6/2.0 | 1.6/2.0 | 1.6/2.0 |
Condensator Diameter/ Length(㎜) | φ14/1900 | φ14/1900 | φ14/1900 | φ14/1900 | φ14/1900 | φ14/1900 | φ14/1900 |
Heat Pipe Material / Thickness(㎜) | Copper tp2/0.6 | Copper tp2/0.6 | Copper tp2/0.6 | Copper tp2/0.6 | Copper tp2/0.6 | Copper tp2/0.6 | Copper tp2/0.6 |
Copper Pipe Diameter/ Thickness | φ35/1.0 | φ35/1.0 | φ35/1.0 | φ35/1.0 | φ35/1.0 | φ35/1.0 | φ35/1.0 |
Joint Specification | φ22 Or 3/4″ | φ22 Or 3/4″ | φ22 Or 3/4″ | φ22 Or 3/4″ | φ22 Or 3/4″ | φ22 Or 3/4″ | φ22 Or 3/4″ |
Insulation Material/ Thickness(㎜) | Rock Wool/40 | Rock Wool /40 | Rock Wool /40 | Rock Wool/40 | Rock Wool /40 | Rock Wool /40 | Rock Wool /40 |
Rated Pressure(MPa) | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 |
Working Temperature(℃) | <120 | <120 | <120 | <120 | <120 | <120 | <120 |
Capacity(L) | 0.89 | 1.26 | 1.48 | 1.63 | 1.93 | 2.00 | 2.37 |
Collecting Area(㎡) | 1.37 | 2.05 | 2.46 | 2.73 | 3.28 | 3.41 | 4.10 |
Gross Area(㎡) | 2.01 | 2.98 | 3.56 | 3.95 | 4.72 | 4.91 | 5.88 |
Referral Traffic(L/min) | 1.06 | 1.49 | 1.79 | 2.0 | 2.4 | 2.5 | 3.0 |
Pressure Drop(Pa) | 16.24 | 41.4 | 63.4 | 81.7 | 127.2 | 140.1 | 219.8 |
Intercept Efficiencyη0 | 0.77 | 0.77 | 0.77 | 0.77 | 0.77 | 0.77 | 0.77 |
Heat Loss Coefficient a W/㎡℃ | 1.9 | 1.9 | 1.9 | 1.9 | 1.9 | 1.9 | 1.9 |
Powe(W)1000W/㎡Irradiation | 744 | 1044 | 1256 | 1398 | 1681 | 1748 | 2098 |
40.25 | 52.75 | 61.75 | 66.75 | 81.00 | 85.35 | 100.70 | |
a (㎜) | 1115 | 1615 | 1915 | 2115 | 2515 | 2615 | 3115 |
b (㎜) | 1025 | 1525 | 1825 | 2025 | 2425 | 2525 | 3025 |
c (㎜) | 950 | 1450 | 1750 | 1950 | 2350 | 2450 | 2950 |
c/2 (㎜) | —— | —— | 875 | 975 | 1175 | 1225 | 1475 |
d (㎜) | 2150 | 2150 | 2150 | 2150 | 2150 | 2150 | 2150 |
e (㎜) | 1375 | 1240 | 1240 | 1240 | 1240 | 1240 | 1240 |
f (㎜) | 1590 | 1590 | 1590 | 1590 | 1590 | 1590 | 1590 |
5. FAQ
1. Can the solar collector be used in cold condition?
Re: This solar collectors can be used in temperatures as low as -30℃, although performance is greatly reduced in such extreme conditions. Good heat output is still achieved in mild sub-zero conditions.
2. What maintenance of the solar collector is required?
Re: Under normal circumstances no maintenance of the system is required. Due to the shape of the tubes regular rainfall and wind should keep the tubes clean. Should a tube even be broken it should be replaced. This, however, is an inexpensive and easy job. Any "handy" person can install a new tube (while adhering to local health and safety regulations). Our solar collectors can operate with several broken tubes, however the efficiency will be reduced slightly.