Loading Port:Ningbo
Payment Terms:TT OR LC
Min Order Qty:-
Supply Capability:60,000PCS pc/month
DX TYPE USED FOR PUMPS
Pressure control is adjustable ,the judgment of water shortage protection is accurate.
It has freedom of rotate 320 degrees, elegant appearance and excellent quality.
It is suitable for self priming pump installation.
Model:DX-01
Normal working voltage :140V~280V
Pressure range:0-10KG
Fluid temperature:0-100
Maximum power:1500W
Maximum current: 20A
Service life :More than 150000 times
How to set
1.Adjust pressure upper limit
A),Short press left key, show pressure upper limit.
Then long press left key 2 seconds, LED show‘PUP’,
go to pressure upper limit adjust.
B),Short press left key=plus 0.1,
long press left key=plus 1.0.;
C),Short press right key=minus 0.1,
long press right key=minus 1.0;
D),Automatically exit after 3 seconds, go to current
displayed pressure.
2.Adjust pressure lower limit
A), Short press right key, show pressure lower limit.
Then long press right key 2 seconds, LED show‘pdn’,
go to pressure lower limit adjust.
B),Short press left key=plus 0.1,
long press left key=plus 1.0.;
C),Short press right key=minus 0.1,
long press right key=minus 1.0;
D),Automatically exit after 3 seconds, go to current
displayed pressure.
3,The power voltage display
A)Long press left key 2 seconds, LED show ‘Vol’, go to show the current power voltage.
B)If long press right key 2 seconds, LED show ‘Vdd’, go to show PCB DC voltage.
C)Short press left key or right key, you can exchange the state of A) and B).
D)Automatically exit after 3 seconds, go to current displayed pressure.
4,ON/OFF
A)Press left key above 5 seconds, you can run or stop the pump.
B)If press right key above 5 seconds, the pump is off, LED shows ‘OFF’and cancel countdown.5.
5,Child Lock
Long press double key 2 seconds, the pressure switch is locked and can’t amend parameter.
The last decimal point shining.
Long press double 2 seconds, remove locked.
6.Countdown
A)Press double above 5 seconds, LED shows‘tHt’, go to adjust countdown.
B)Short press left key=plus 0.1 hour=6 minutes. Long press left key= plus 1.0 hour.
CShort press right key= minus 0.1 hour. Long press right key= minus 1.0 hour.
D)Time is over, you can stop or run pump. If you stop pump, will show ‘OFF’.
E)Press right key above 5 seconds, countdown will cancel. The pump is off ,and show ‘OFF’.
Warning information
1.‘12.3’ or‘4.5’or‘P6.7 = current pressure display format, unit kg/cm².
2.‘EUH’ means Error High voltage, power voltage is greater than 265Vac.It is safer.
3.‘EUL’ means Error low voltage, power voltage is less than 145Vac.It is safer.
4.‘SEn’ means Senscr Error. It will stop.
5.‘PLO’ means Low Pressure.
6..‘dry’ means real dry. It is no water safly. If you want to run the pump, you will run manually.
7.‘HZO’ means no water. The pump will restart within 5 minutes if no water.
8.‘OFF’ means turn off.
9.‘SPH’ means deadhead. The pressure can’t reach upper limit. The pump will stop.
10.‘t1.2’ means timer, unit is hour. Also the pressure shows double digit, unit Bar,
For example ‘P3.4’.