Duplex Service Drop AAC-Aluminum conductor

Loading Port:Tianjin

Payment Terms:TT OR LC

Min Order Qty:100 m

Supply Capability:100000 m/month

Product Description:

1.Duplex Service Drop AAC-Aluminum conductor
1.1 Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75°C maximum.
1.2 Standards
·  B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
·  B-231 Aluminum Conductors, Concentric-Lay-Stranded.
·  B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
·  B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.
·  B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
·  Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
1.3 Specification

Items Phase Conductor Size Phase Conductor Stranding Phase Conductor Insulation Thickness Bare Neutral Messenger Size Bare Neutral Strand Bare Neutral Messenger Breaking Strength Weight Per KM -XLPE
 AWG
mm AWG
N Kg/Km
Pekingese 6 Solid 1.143 6 7/w 2504.224 94.49
Collie 6 7/w 1.143 6 7/w 2504.224 99.40
Dachshund 4 Solid 1.143 4 7/w 3918.688 142.10
Spaniel 4 7/w 1.143 4 7/w 3918.688 149.54
Doberman 2 7/w 1.143 2 7/w 6004.8 227.22
Malemute 1/0 19/w 1.524 1/0 7/w 8851.52 360.99

 2.Duplex Service Drop ACSR Neutral-Messenger Aluminum Conductor2.1 Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75°C maximum.
2.2 Standards
·  B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
·  B-231 Aluminum Conductors, Concentric-Lay-Stranded.
·  B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
·  B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.
·  B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
2.3 Specification

Items Phase Conductor Size Phase Conductor Stranding Phase Conductor Insulation Thickness Bare Neutral Messenger Size Bare Neutral Strand Bare Neutral Messenger Breaking Strength Weight Per KM -XLPE
 AWG
mm AWG
N Kg/Km
Setter 6 Solid 1.143 6 6/1 5293.12 111.60
Shepherd 6 7/w 1.143 6 6/1 5293.12 116.51
Eskimo 4 Solid 1.143 4 6/1 8273.28 169.19
Terrier 4 7/w 1.143 4 6/1 8273.28 176.63
Chow 2 7/w 1.143 2 6/1 12676.8 270.37
Bull 1/0 19/w 1.524 1/0 6/1 19482.24 429.59

· 












Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
3.Duplex Service Drop AAAC 6201 Alloy Neutral Messenger Aluminum Conductor3.1 Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75°C maximum.
3.2 Standards
·  B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
·  B-231 Aluminum Conductors, Concentric-Lay-Stranded.
·  B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
·  B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.
·  B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
·  Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
3.3 Specification

Items Phase Conductor Size Phase Conductor Stranding Phase Conductor Insulation Thickness Bare Neutral Messenger Size Bare Neutral Strand Bare Neutral Messenger Breaking Strength Weight Per KM -XLPE
 AWG
mm AWG
N Kg/Km
Chihuahua 6 Solid 1.143 6 7 4937.28 100.5888
Vizsla 6 7/w 1.143 6 7 4937.28 105.4992
Harrier 4 Solid 1.143 4 7 7828.48 151.776
Whippet 4 7/w 1.143 4 7 7828.48 159.216
Schnauzer 2 7/w 1.143 2 7 12454.4 242.9904
Heeler 1/0 19/w 1.524 1/0 7 19838.08 385.6896

4.Triplex Service Drop Aluminum Conductors AAC Neutral-Messenger
4.1 Applications
To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volts or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene Insulation or 90°C maximum for crosslinked insulation.
Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC neutral messenger.
Standards
·  B-230 Aluminum Wire 1350-H19 for Electrical Purposes
·  B-231 Aluminum Conductors, Concentric-Lay-Stranded
·  B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
·  B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors
·  B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
·  Triplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA body S-76-474
4.3 Specification

Items Phase Conductor Size Phase Conductor Stranding Phase Conductor Insulation Thickness Bare Neutral Messenger Size Bare Neutral Strand Bare Neutral Messenger Breaking Strength Weight Per KM -XLPE
 AWG
mm AWG
N Kg/Km
Haiotis 6 Solid 1.143 6 7 2504.224 148.42
Patella 6 7/w 1.143 6 7 2504.224 157.98
Fusus 4 Solid 1.143 4 7 3918.688 219.95
Oyster 4 7/w 1.143 4 7 3918.688 234.29
Clam 2 7/w 1.143 2 7 6004.8 352.15
Murex 1/0 7/w 1.524 1/0 7 8851.52 572.10
Purpura 1/0 19/w 1.524 1/0 7 8851.52 559.07
Nassa 2/0 7/w 1.524 2/0 7 11164.48 703.44
Melita 3/0 19/w 1.524 3/0 19 14722.88 847.37
Portunus 4/0 19/w 1.524 4/0 19 17880.96 1048.21
Nannynose 336.4 19/w 2.032 336.4 19 27337.408 1680.26

5.Triplex Service Drop Aluminum Conductors with Full Size ACSR Messenger
5.1 Applications
To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volts or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene Insulation or 90°C maximum for crosslinked insulation.
5.2 Standards
·  B-230 Aluminum Wire 1350-H19 for Electrical Purposes
·  B-231 Aluminum Conductors, Concentric-Lay-Stranded
·  B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
·  B-309 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors
·  B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
·  Triplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA body S-76-474