CPT,Vertical, radially split shaft-driven sump pump

Loading Port:Shanghai

Payment Terms:TT OR LC

Min Order Qty:1 unit

Supply Capability:10 unit/month

Product Description:

Design
Vertical, radially split shaft-driven sump pump radial impeller, single-flow, single-stage.                                
Applications
Used in the chemical and petrochemical industry as well as in refineries for handling chemically aggressive media with only low solids content.                                                        

Overview of technical data

Type of impeller                                                                         Radial                    
Impeller material (EN standard)                                                                         1. 4408;JL 1040                    
Type of bearing                                                                         Ball and plain bearings                    
Drive frequency                                                                         50 Hz / 60 Hz                    
Maximum speed of rotation                                                                         3. 500                    
Maximum flow rate                                                                         190                         m³/h                    
Maximum discharge-side pressure                                                                         16                         bar                    
Casing material (EN standard)                                                                         JL 1040; 1.4408                    
No. of impeller entries                                                                         Single entry                    
Casing material                                                                         Stainless steel; Cast iron                    
Minimum flow rate                                                                         2                         m³/h                    
Drive voltage                                                                         Low voltage                    
eClass assignment                                                                         36410101                    
Pump set location                                                                         Dry installed                    
Heatable                                                                         Yes                    
Max. permissible fluid temperature                                                                         300                         °C                    
UNSPSC classification                                                                         4015150300                    
Main applications                                                                         Industry and process engineering; Oil / Gas                    
Type of installation                                                                         Stationary                    
Type of casing                                                                         Volute casing                    
Type of connection                                                                         Flange                    
Type of lubrication                                                                         Oil lubrication                    
Type of drive                                                                         Electric motor                    
Installation position                                                                         Vertical                    
Shaft material (EN standard)                                                                         C 45; 1.4571                    
Shaft seal type                                                                         Mechanical seal; Gland packing                    
Maximum head                                                                         150, 00                         m                    
Minimum head                                                                         2, 00                         m                    
Nozzle position                                                                         End suction                    
Casing partition                                                                         Radially split