Complete set of AC filter capacitor

Loading Port:China Main Port

Payment Terms:TT OR LC

Min Order Qty:-

Supply Capability:-

Product Description:


Complete set of AC filter capacitor


1. Introduction

Complete set of ACfilter capacitor in the power frequency system is used for filtering harmfulharmonic current in the power system to improve power quality and increasepower factor of system.


2. Structure

The complete set consists of AC filtercapacitor, filterreactor, disconnecting switch, earth switch, lightning rod, fuse protector, dischargecoil, current transformerinsulator, busbar and steel frame (Each can be set upon customer’srequirement)

The main methods of connecting wires are single star or double star, relay protection methods are open-delta voltage protection, differential current protection, differential voltage protection, neutral point unbalanced current protection and so on.

Capacitordischarge modes have discharge resistance (placed in the internal capacitors)and discharge coil.


3. Serviceenvironment

Installation site: Indoor, outdoor, plateau, moistheat, sordid place andso on

  Temperature: -40℃~+40




4. Technical parameters

Type

Rated voltage

kV

Total capacity

(kvar)

Capacity per unit

(kvar)

Connection mode

Outline dimension

(m)

Layout

Arrangement mode

TAL  10-1050/50AK

10

1050

50

Y

Open delta voltage

1.75x4.1x1.2

Indoor, single layer, single phase

TAL 10-2700/100AK

10

2700

100

Y

Open delta voltage

1.8x3.8x2.4

Indoor, double layers, single phase

TAL 10-3000/200AK

10

3000

200

Y

Open delta voltage

1.85x4.1x1.4

Indoor, single layer, single phase

TAL  10-13500/250BL

10

13500

250

Y-Y

Unbalance current at neutral point

9.6x1.5x2.7

Indoor, three layers

TAL 10-6000/250BL

10

6000

250

Y-Y

Unbalance current at neutral point

3x1.3x2.9

Indoor, three layers

TAL 35-12024/334BL

35

12024

334

Y-Y

Unbalance current at neutral point

2.2x4.4x3.6

Indoor, double layers, single phase

TAL 35-14400/300AK

35

1400

300

Y-Y

Unbalance current at neutral point

3.2x4.4x3.6

Indoor, double layers, single phase

TAL 110-10800/180BL

110

10800

180

Y-Y

Unbalance current at neutral point

9.5x3.5x6.2

Indoor, three layers, single phase

TAL 110-15180/230BL

110

15180

230

Y-Y

Unbalance current at neutral point

9.5x3.5x6.2

Indoor, three layers, single phase

5. Model coding





Endnotes No.:

First letter (Mainmode of connection)

A—Singlestar(Y)connection

B—Doublestar(Y—Y)wire connection


Second letter(Relayprotection)

C—Voltagedifferential protection

L—Unbalancedcurrent protection

K—Parallelport triangle voltage protection

Q—Bridgetype difference stream protection




Electrical schematic diagram

No.

Name

Code

1

Zinc oxide arrester

FV

2

Filter reactor

L

3

Filter capacitor

C

4

Current transformer

TA