Loading Port:Shekou
Payment Terms:TT or LC
Min Order Qty:20 pc
Supply Capability:1000 pc/month
1000kW integrated central inverter solution with DC distributed box and ac distributed box.
High conversion efficiency of 98.7% deliver more energy
Powerful grid management functions (including LVRT)
Active power continuous adjustment (0-100%)
Reactive power continuous adjustment (0-100%)
Integrated with SCADA monitoring system, totally compatible with smart-grid interface
Intelligent control, entirely meet the requirements of grid
Provide a turnkey solution, easy installation and maintenance
Comprehensive protection for overvoltage, islanding, short-circuit, overload, etc.
CP1000 Station | CP1260 Station | |||
Input data | ||||
Max. DC power | 1150kW | 1450kW | ||
Max. DC voltage | 1000V | 1000V | ||
PV voltage range | 500V-1000V | 500V-1000V | ||
MPP voltage range/nominal voltage | 500V-850V | 500V-850V | ||
Rated Input voltage | 600V | 600V | ||
Start voltage/power | 520V/10000W | 520V/12600W | ||
Maximum Input current | 2240A | 2900A | ||
Number of MPP trackers/strings per MPP tracker | 1 | 1 | ||
Max. input current/per string | 2*10 | 2*10 | ||
Output (AC) | ||||
Rated AC output power | 1000kVA | 1000kVA | ||
Rated AC voltage | 315V | 315V | ||
AC voltage range | 250V-362V | 250V-362V | ||
Rated frequency | 50Hz/60Hz | 50Hz/60Hz | ||
Frequency Range | 45Hz-55Hz/55Hz-65Hz | 45Hz-55Hz/55Hz-65Hz | ||
Rated Output Current | 1833A | 2310A | ||
Maximum Output Current | 2016A | 2592A | ||
Power factor | 0.9lagging-0.9leading | 0.9lagging-0.9leading | ||
THDI | <3%(@Pac,r) | <3%(@Pac,r) | ||
Efficiency | ||||
Max. efficiency | 98.70% | 98.70% | ||
Euro-eta | 98.50% | 98.50% | ||
MPPT efficiency | 99.9% | 99.90% | ||
Protection Devices | ||||
DC disconnection device | DC circuit breaker | DC circuit breaker | ||
AC disconnection device | AC circuit breaker | AC circuit breaker | ||
DC overvoltage protection | Surge arrester type II | Surge arrester type II | ||
AC overvoltage protection | Surge arrester type II | Surge arrester type II | ||
Grid monitoring/Management | yes/yes | yes/yes | ||
Ground monitoring | yes | yes | ||
Over temperature protection | yes | yes | ||
Insulation monitoring | yes | yes | ||
General data | ||||
Dimension (W/H/D)in mm | 3600/3000/2896 | 3600/3000/2896 | ||
Weight | 6000KG | 6000KG | ||
Operating Temperature Range | -25℃ ... +55℃ | -25℃ ... +55℃ | ||
Relative Humidity | 0~95% | 0~95% | ||
Degree of Protection | IP54 | IP54 | ||
Noise Emission | 65dB(A)@1m | 65dB(A)@1m | ||
Maximum Operating Altitude | 6000m(Derating over 3000m) | 6000m(Derating over 3000m) | ||
Standby consumption | <200W | <200W | ||
Cooling | Air forcedl | Air forcedl | ||
Topology | Transformerless | Transformerless | ||
Display | Touch screen LCD | Touch screen LCD | ||
Communication Interface | RS485/Ethernet | RS485/Ethern | ||
Certificates and ApprovalsCE, TUV, CGC, LVRT, ZVRT, PEA, G59 |
FAQ
1. Have any design tool and how to use it?
Shine Design is the system design software just for inverters, It can conduct installers to figure out panel numbers for a system, panel numbers for each string, and which inverter model is suitable for the system. Moreover, it can print a design report after input all necessary parameters, can calculate DC/AC wire wastage, annual generation, etc.
2. Does the inverter have monitoring solutions for residential system?
For small rating system, we have wired two monitoring solution (ShineNet via RS232 or RS485). (a) Local wireless monitoring solution (ShineVision via RF module communication) (b) Global wireless monitoring solution (WIFI module via WIFI network)
3. Do you have free solution for monitoring?
ShineNet is an inverter monitoring software run in Windows XP, Windows Vista, Windows 7 operating system. It can monitor inverter via RS232 (or RS232 convert to USB cable) and RS485 wire connection. Customers can purchase the cable locally to get the inverter monitored, it is simple.