Burner for Styrene Steam Superheater

Loading Port:China Main Port

Payment Terms:TT OR LC

Min Order Qty:-

Supply Capability:-

Product Description:

The type of double radiant vertical tube box is mostly used for Steam Superheater for Styrene Unit. The fluid is superheat steam in tubes. The temperature of firebox shall be more than 1000℃, heavy losses will be created because of the tube swelling and rupture caused by the local overheat of tube. YX/ZGQ-xx Burners manufactured by Corporation has good radiant uniformity because the flame is straight and powerful and the flame dimension matches with the tube arrangement. Natural draft is used for this type of Burners and inlet mufflers shall be equipped. Flat flame is often used for Steam Superheater for Styrene Unit. Dehydrogenation and hydrocarbonylation off gas are used as main fuel and pipe network gas as compensation.

Ethylene Cracking Heater belongs to Chemical Reaction Heater, fluid will be cracked by catalyst in tubes directly. The cracking of high molecular compound needs high temperature, so, the firebox temperature of Ethylene Cracking Heater is usually more than 1150℃ and tubes shall be heated uniformly. Lots of Burners shall be arranged at the bottom and side walls to meet above requirements. Burners at the bottom often use gas or combination of oil & gas as fuel to provide the 70% of heat productivity. Burners at side walls shall be Flameless Burners and the flame is attached to Walls in round shape.

The initial designed load of H-116 for cracking naphtha is 19.3t/h, 20.3t/h for cracking hydrogenation tail oil and 18.77t/h for cracking diesel oil, while the actual maximum feeding load is only 85~90% of the designed load. If the load is exceed 90%, Burner can not keep smooth burning because of serious over temperature at Convection Section. The operation safety can not be guaranteed under this condition. After replacing new Burner, the load of Cracking Heater had reached to 19.3t/h in first operation cycle and 19.6t/h in second operation cycle in good condition which had helped to save the fuel, increase the capacity of treatment and lower the temperature of flue gas. Thermal efficiency of H-116 is more than 93.5% which was increased 0.5~1% after replacing new Burner, so the coke-burning cycle was greatly extended.

GROUP mainly produces the following products:

l  Refinery/chemical furnaces, incinerators, coal (liquid) chemical reformers

l  Waste heat boilers, thermal medium boilers

l  Class A1 /A2 pressure vessels

l  Reactors, Heat Exchangers & Towers

l  Oil tanks/accessories/mixers, alloy steel precision castings

l  Four classes of piping supports and hangers used in fired-electric/thermo-electric/nuclear electric power industries and dampers

l  Flue gas/air/coal powder duct and its attachments

Boiler ancillaries, water treatment devices and so on