Self-check: automatical or manual internal fault inspection
Print: Automatically or manually print
Display :Large screen LCD
Adopts dynamic compensation method, fundamentally solve the compensation system series resonance overvoltage and best compensation between conflicting issues. It is well known that the arc suppression coil without any benefits during normal operation of power grids, if then tune into a state of full compensation or close to full compensation, there will be a series resonance overvoltage by raising the neutral point voltage, power grid normal operation and all sorts of single-phase grounding fault may produce dangerous overvoltage. So when the normal operation of power grids, adjust the arc suppression coil makes the tracking grid of capacitive current change bad no, which is specified by the department of electric power "fixed arc suppression coil can't work in a state of full compensation or close to full compensation". Like domestic automatic compensation device are servo system, is in front of the grid has not yet occurred ground fault the arc suppression coil to adjust to a state of full compensation for ground fault occurs, it is to avoid excessive series resonance overvoltage and a damping on the arc suppression coil in series
THXH series arc-suspension coil complet compensation installation can change inductive current compensation of the arc suspension coil by changing inductance L. Advantages: strong adaptability in electrical network, extremely short response time and automatic detection and identification of the running status of electrical network via computer-based controller. During normal operation of the electric network, it can real-time calculate the capacitive current of the power network to earth and the out-of-resonance of power compensation network. It can realize quick and rational compensation in case of single-phase earthing.
(1), using the technology of controllable silicon, the compensation current is 0 ~100% of rated current range of continuous stepless adjustment, realize large-scale precise compensation, but also to adapt to the different needs of the powerdistribution network in different development period.
(2), the use of short circuit impedance as the working resistance, the volt ampere characteristic in the range of 0 to 110%UN is maintained in excellent linearity,which can achieve precise compensation.
(3), the arc suppression coil with adjustable belongs to, do not need to be installed damping resistance, also won't appear a series resonant, it not only improves the reliability of the operation, but also simplifies the equipment.
(4) when a single-phase earth fault occurs in the arc suppression coil is the fastest 5ms output compensation current, thereby suppressing arc, prevent airionization caused by arc caused by phase to phase short circuit; at the same time, it can effectively eliminate the repeated single-phase grounding fault are separated by a short time.
(5), complete sets of equipment without transmission, a rotating mechanism, high reliability, low noise, simple operation and maintenance.