Loading Port:Shekou
Payment Terms:TT OR LC
Min Order Qty:5 pc
Supply Capability:99999 pc/month
1. 6KVA Online UPS 220VAC
2.Long backup time
3.High frequency and double convrsion online technoloy
4.LCD or LED
6KVA Online UPS 220VAC
Features:
1.Double conversion online technology
2.MCU intelligent control
3.Wide input voltage range
4.LCD LED user interface
5.optional 110/230 output voltage
6.Cold start
7.Short circuit and overlaod protection
8.Self test when ups start
9.Auto restart after utility power restore when ups shutdown due to battery low
10.Over temperature and over voltage protection
11.Optional extension battery pack
12.EM/RF noise filter
13.Smart rs232 communication with monitoring software
14.Optional SNMP card slot
Model | 6KN/6KS | 10K/10KS | 3P10KS | 3P15KS | 3P20KS |
Power Capacity | 6KVA/4.2KW | 10KVA/7W | 10KVA/7W | 15KVA/10.5W | 20KVA/14W |
Input | |||||
Related voltage | 220V | ||||
Voltage range | 176~276VAC | 304~478VAC | |||
Phase | Single | 3Phase | |||
Power factor | 0.98 | 0.95 | |||
Connextion | Hardwire | ||||
Output | |||||
Voltage | 220VAC +_1% | ||||
Frequency Range | The same as utility frequency(Line Mode),60HZ/50Hz+_0.2Hz(Battery mode) | ||||
Waveform | Pure sine Wave | ||||
Power factor | 0.7 | ||||
Voltage Distortion | Less than 0.2 under liner load | ||||
Current Crest Ratio | 3:1 Max | ||||
Overlaod Capacity | Line mode:105%<load<150% for 10mins,or Laod >130% for 300ms,then transfer to bypass alarm | ||||
Battery mode:105%<Load<150% for 30s & load>150% for 300ms,then trun off ouput &alarm | |||||
Battery | |||||
Type | Sealed-lead Acid Maintenance free battery | ||||
Backup time | 5min | N/A | |||
Recharge time | 8hrs to 90% of capacity after full laod discharge | ||||
Transfer time | 0ms | ||||
Maintenance Bypass Switch | Yes | ||||
LED LCD Indicators | |||||
Status | Load lever/Battery lever/battery /Untiliy power inverter, Bypass, Overload, Fault | ||||
Audible Alarm | |||||
Condition | Bypass/Battery Mode/Battery low/Overload/Fault | ||||
Bypass | Alarm beeps every 2minuts | ||||
Battery discharge | Alarm beeps every 4 seconds/Every second if battery low | ||||
Overlaod | Alarm beeps twice every second | ||||
Fault | Alarm beeps continuously | ||||
Acoustic Niose | |||||
At 1 meter distance | <55dBA | 60dBA | |||
Communications | |||||
DB-9 Port | RS232 Serial Interface | ||||
Intelligent Slot | Options:Webpower, AS400 or Winpower CMC | ||||
Environmental | |||||
Operating Temperature | 0~40°C | ||||
Operating Humidity | 20~90% non-condensing | ||||
Net Weight | 90/46 | 93/38 | 45 | 55 | 55 |
Dimensions(W*D*H) | 260*570*717 |