Loading Port:Shanghai
Payment Terms:TT OR LC
Min Order Qty:10 unit
Supply Capability:100 unit/month
Specifications
3kW frequency and voltage stabilizer converter/inverter AC50-11030 single-phase
1.Reliability
2.Interface-friendly
3kW frequency and voltage stabilizer converter/inverter AC50-11030 single-phase
Product Discription
The power adopts advantaged SPWM IGBT high-frequency inverter technology, internal structure is AC-DC-AC, thoroughly eliminate the network interference, output waveforms are pure. It has the following features: wide range of constant-voltage and constant-frequency, high precision, light weight, small capacity, output transformer with apartheid, with the good with a high quality uninterrupted power supply system.
1.Input voltage: 130~280V
2.Input frequency: 30~70Hz
3.Output voltage: 220V/380V±0.5%
4.Output frequency:50Hz±0.01%
5.Wave distortion: <1%
6.Isolation transformer output, safe and credible
7.Auto-protection and alarm for output overvoltage, over current, overheat, short circuit
8.Efficiency reach above 90% ,widely applicable load,for nasty, capacitive resistance,any combination of the load
Product Parameter
Model | 11005 | 11010 | 11030 | 11050 | 11100 | 31150 | 31200 | 313000 | 31450 | 311000 | ||
Capacity(VA) | 500 | 1K | 3K | 5K | 10K | 15K | 20K | 30K | 45K | 100K | ||
Output currency | 2.1 | 4.2 | 12 | 21 | 42 | 63 | 84 | 125 | 188 | 420 | ||
Circuit model | IGBT/SPWM pulse width adjustment mode | |||||||||||
AC Input | Voltage | 130V-280V | 265V-495V | |||||||||
Frequency | 30-70Hz | |||||||||||
Phase | single phase | three phase four wire | ||||||||||
AC output voltage | 220V±1% | |||||||||||
Output frequency | 50Hz/60Hz | |||||||||||
frequency stability | ≤±0.01% | |||||||||||
Voltage stability | ≤1% | |||||||||||
Wave distortion | ≤2% | |||||||||||
Reaction time | ≤2mS | |||||||||||
frequency meter | 0.1Hz | |||||||||||
Voltage meter | 0.1V | |||||||||||
Current meter | 0. 1A | |||||||||||
Power meter | 0.1W | |||||||||||
Efficiency | efficiency more than 90% ,be suit for wide-load, can be for the inductive, capacitive, resistive, and any mixed loads. | |||||||||||
Protection function | The importation of non-fuse switch, without output fuse switch, the electronic circuit to detect over-voltage Express .Over voltage, over current, over temperature, over load, short circuit, and automatic alarm. | |||||||||||
Insulation reactance | 500Vdc 20MΩ | |||||||||||
Pressure endurance insulation | 1500Vac/5mA/1min | |||||||||||
Cooling model | Compulsive fan cooling | |||||||||||
Working temperature | -10℃-45℃ | |||||||||||
Relative humidity | 0-90%(No condensing) | |||||||||||
Altitude | 1500meters | |||||||||||
Dimension (W×L×H)mm | 410*440*135 | 460*440*220 | 560*350*600 | 660*400*700 | 830*450*1100 | 1160*520* 1370 |
FAQ
What is the delivery time?
We can delivery the equipment within 5 days after receiving your payment.