1KVA/2KVA/3KVA Online UPS input voltage (110V–300V)

Loading Port:Shekou

Payment Terms:TT OR LC

Min Order Qty:100 pc

Supply Capability:30000 pc/month

Product Description:

Main Features

True double-conversion

Microprocessor control optimizes reliability

Input power factor correction

Output power factor 0.8

Wide input voltage (110V–300V)

Converter mode available

ECO mode for energy saving

Generator compatible

Charger capacity expansion to 6A for long-run models

Smart SNMP works well with either USB or RS-232 together

Comprehensive display allows easy monitoring and access of UPS status



PHASE Single phase with ground

CAPACITY 1000VA/800W 2000VA/1600W 3000VA/2400W 1000VA/800W 2000VA/1600W 3000VA/2400W

INPUT

Nominal Voltage 200/208/220/230/240VAC 200/208/220/230/240VAC

Voltage Range 110-300 VAC ± 5 % (Based on load at 50%)

160-300 VAC ± 5 % (Based on load at 100%) 110-300 VAC ± 5 % (Based on load at 50%)

160-300 VAC ± 5 % (Based on load at 100%)

Frequency Range 40Hz ~ 70 Hz

Power Factor ≧0.99 @ Nominal Voltage (100% Load)

OUTPUT

Output Voltage 200/208/220/230/240VAC 200/208/220/230/240VAC

Voltage Requlation ± 1 % ± 3 %

Frequency Range 

(Synchronized Range) 47~ 53 Hz or 57 ~ 63 Hz

Frequency Range (Batt. Mode) 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz

Current Crest Ratio 3:1

Harmonic Distortion ≦ 3 % THD (Linear Load) ;

≦ 6 % THD (Non-linear Load) ≦ 3 % THD (Linear Load) ;

≦ 6 % THD (Non-linear Load)

Transfer Time AC to DC Zero

Inverter to Bypass 4 ms (Typical)

Waveform (Batt. Mode) Pure Sinewave

EFFICIENCY

To AC Mode 87% 90% 90% 87% 90%

To Battery Mode 83% 87% 89% 83% 87% 89%

BATTERY

Standard Model Battery Type 12 V / 7 Ah 12 V / 7 Ah 12 V / 9 Ah 12 V / 7 Ah 12 V / 7 Ah 12 V / 9 Ah

Numbers 2 3 6 8 6 8 2 3 6 8 6 8

Typical Recharge Time 4 hours recover to 90% capacity

Charging Current (Max.) 1.0 A

Charging Voltage 27.3VDC ± 1% 41.0VDC ± 1% 82.1 VDC ±1% 109.4

VDC±

1% 82.1 VDC ±1% 109.4

VDC

±1% 27.3VDC

±1% 41.0 VDC

±1% 82.1 VDC ±1% 109.4

VDC±

1% 82.1 VDC ±1% 109.4

VDC±

1%

Long-run Model Battery Type Depending on the capacity of external batteries

Numbers

Charging Current (Max.) 1.0A/2.0A/4.0A/6.0 A ±10%

Charging Voltage 27.3

VDC±1% 41.0

VDC±1% 82.1

VDC±1% 109.4

VDC±1% 82.1

VDC±1% 109.4

VDC±1% 27.3

VDC±1% 41.0

VDC±1% 82.1

VDC±1% 109.4

VDC±1% 82.1

VDC±1% 109.4

VDC±1%

INDICATORS

LCD or LED Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators

ALARM

Battery Mode Sounding every 4 seconds

Low Battery Sounding every second

Overload Sounding twice every second

Fault Continously sounding