Loading Port:China Main Port
Payment Terms:TT or LC
Min Order Qty:1 Piece pc
Supply Capability:2000 Pieces per Week pc/month
Outstanding feature
1. Texas Instruments processor
2. Motorola Microprocessor
3. Module design
4. Advanced Current Control
5. IGBT power component
6. Power Factor Correction
7. Online Maintenance
8. High frequency and double conversion on-line technology
9. Advanced PFC technology
10. EPO Function
11. Wide input voltage range
12. Fully digitized microprocessor control
13. Parallel redundancy
14. Advanced battery management
15. Lightning and surge protection, short circuit and overload protection
16. Multilingual LCD display
Technical specification
MODEL | 6K(S)L | 10K(S)L | 3CRT10KSL | 3CRT15KSL | 3CRT20KSL |
Power(VA/Watt) | 6000VA/4200W | 10000VA/7000W | 10000VA/7000W | 15000VA/10500W | 20000VA/14000W |
INPUT | |||||
220 VAC, 1 Phase + Neutral | 220 VAC, 1 Phase + Neutral | 380 VAC, 3 Phase + Neutral | 380 VAC, 3 Phase + Neutral | 380 VAC, 3 Phase + Neutral | |
Voltage Tolerance | 176 – 276 VAC ± 3% | 176 – 276 VAC ± 3% | 304 – 478 VAC ± 3% | 304 – 478 VAC ± 3% | 304 – 478 VAC ± 3% |
Power Factor | ≥ 0.98 | ≥ 0.98 | ≥ 0.95 | ≥ 0.95 | ≥ 0.95 |
Current (nominal) | 23 Ampere | 37 Ampere | 13 Ampere / Phase - 39 A | 23 Ampere / Phase - 69 A | 30.3 Ampere / Phase - 91 A |
Input Fuse | 32 A NFB | 50 A NFB | 63 A NFB | 100 A NFB | 100 A NFB |
Frequency & FrequencyRange | 50 Hz, 46 ~ 54 Hz | ||||
Perfect Voltage and frequency Compatibility | |||||
0.65 inductive - 1.0 resistive | |||||
Sinusoidal | |||||
220 / 230 / 240 VAC ± 1% | |||||
At 50% - 100 - 50% unbalanced load, max voltage decline < ± 5% | |||||
At Dynamic load Changes, Output Voltage recovery time is 60 msec ± 1% | |||||
For Linear Load ≤ 2%, Non Linear Load ≤ 6% | |||||
50 Hz / Mains 46-54 Hz, Battery Mode ± 0.1% (0.05 Hz) | |||||
3:1 | |||||
For 105% - 130% load 10 mins., for > 130% load transfer to bypass after 1 sec, shutdown after 1 min at overloaded bypass | |||||
At > 105% load shut down after 10 sec. | |||||
Standard static bypass, Completely Uninterrupted transfer between Mains - Battery / Battery - Mains | |||||
176 – 261 VAC, 1 Phase + Neutral | |||||
Maintenance Free, Dry Type | |||||
240 VDC | |||||
LCD Panel | |||||
Push Buttons (Open / Close, Audible Alarm Cancellation) | |||||
% Load, Input Voltage Exist, Output Voltage Exist, Bypass Active, Battery Mode, Battery Capacity (%), Inverter in Service, Fault | |||||
Mains On, Mains Reverse, Battery Mode, Bypass On, Load / Battery Level, Overload, Fault | |||||
Electronic Protection is available. In case of exceeding limits, the load is transferred to bypass without any interruption | |||||
Inverter shuts down automatically | |||||
If the internal Temperature is 90°C the load is transferred to bypass, When it returns < 80°C, Inverter starts to work | |||||
Modem / Network protection input against to Voltage Spikes | |||||
Buzzer, it can be switched off by audible alarm button. | |||||
Battery Mode, Battery Low, UPS fault, Overload, Short Circuit, Over Charge, Charger, Bypass, Inverter fault, Communication fault | |||||
Standart DB 9 (Female) Port, Intelligent RS232 (standard), SNMP(optional) and DB25 parallel port (for paralelling, optional) | |||||
Winpower-XP | |||||
88% | |||||
≤ 55 dBA | ≤ 60 dBA | ||||
EN 61000-4-2 (ESD), 4-3 (RS), 4-4 (EFT), 4-5 (surge), IEC 62040-2 (EMI) | |||||
0 °C ~ 40 °C, maximum 20-90% (Non Condence) | |||||
-20 °C ~ +70 °C | |||||
IP20 | |||||
Forced cooling with variable speed fan according to load % | |||||
≤ 1000 meter (from the sea level), at nominal load | |||||
260x717x570 | |||||
35 / 84 | 38 / 93 | 38.5 | 55 | 55 |