                  I. Product Properties:

                  1. The products shall comply with GB14049-93 national standards.
                2. The cable's insulation resistance is not less than 1500MΩ.km (20 ℃).
                 3. After the cable is soaked in water for one hour, it can withstand 18kv high voltage tests and can not be breakdown for one minute.
                   II. Use characteristics:
                  1. This product is applied to overhead electric power with AC rated voltage U (Um) of 10 (12) kv.
                  2. The maximum long-term working temperature of cable conductor is 90 ℃.
                  3. The laying temperature should not be less than -20 ℃.
                 4. When short circuit (the longest duration should be less than 5 seconds) occurs, the maximum temperature of the conductor should not exceed 250 ℃.
                 


Type and Specification:
                     

Type

Number of cores

Cross-section

Description

Main use

JKYJ

1

25-240

Copper core cross-linked PE insulated overhead cables

When overhead fixed lying is carried out, flexible copper core products are used as transformers' down lead. When cables are set up, it should be considered that cables and trees shall be maintained in a certain distance, and when the cable is in operation, cables are allowed to contact trees frequently.

3

25-120


1

25-240

Flexible copper core cross-linked PE insulated overhead cables

JKTRYJ

3

25-120

Structure, size, and technical performance
                                                                       

Specification

Outer diameter of pressed conductor

Internal shielded thickness

Insulation thickness

Outer diameter of the cable

Cable Weight

Conductor pull-off force

Maximum resistance of the conductor

Water immersion AC voltage test

mm

mm

mm

mm14.2

kg/km

N

20℃Ω/km

KV

1×25

6.2

0.6

3.4

14.2

344

8465

0.749

18

1×35

7.2

0.6

3.4

15.2

445

11731

0.540

18

1×50

8.5

0.6

3.4

16.5

594

16502

0.399

18

1×70

10.2

0.6

3.4

18.2

792

23461

0.276

18

1×95

11.8

0.7

3.4

20.0

1034

31759

0.199

18

1×120

13.2

0.7

3.4

21.0

1280

39911

0.158

18

1×150

14.8

0.7

3.4

23.0

1566

49505

0.128

18

1×185

16.4

0.7

3.4

24.6

1897

61846

0.1021

18

1×240

18.6

0.7

3.4

26.8

2413

79823

0.0777

18