Loading Port:China main port
Payment Terms:TT or LC
Min Order Qty:1 pc
Supply Capability:1000 pc/month
ZTY series high accuracy fully automatic AC stabilized Power Supply is a key series of our stabilizing products. It mainly consists of auto-transformer, servo motor, automatic control circuit. When the utility is not stable or the load fluctuates, the automatic control circuit modifies the control output according to the input voltage change of power supply, with driving the servo motor, and then the servo motor adjusting the carbon brush of auto-transformer to regulate the output voltage at its rating and remain stable.
Single Phase | |||||||||
VA Rating | 0.5KVA | 1KVA | 2KVA | 3KVA | 5KVA | 10KVA | 15KVA | 20KVA | 30KVA |
INPUT | |||||||||
Phase | Single Phase+N+GND | ||||||||
Voltage Range | 160Vac-250Vac | ||||||||
OUTPUT | |||||||||
Voltage | 220V | ||||||||
Voltage Precision | ≤±3% | ||||||||
Frequency | 50/60Hz | ||||||||
Over-Voltage Protection | Output Voltage 250V±5V | ||||||||
Low-Voltage Protection | Output Voltage 183V±5V | ||||||||
Efficiency | ≥96% | ||||||||
OTHERS | |||||||||
Display Mode | LED / METER | ||||||||
Input/Output Device | Optional Plug; Socket / Terminal | ||||||||
Waveform Distortion | No affixation Waveform Distortion | ||||||||
Response Time | (±10% Varies) <1s | ||||||||
Insulation Resistance | ≥2MΩ | ||||||||
Anti-Electricy Intension | Low frequency sine voltage 1500V take 1 minute no rout and camber phenomena | ||||||||
Ambient Temperature | 0℃-40℃ | ||||||||
Relative Humidity | ≤95% | ||||||||
Working | Continue | ||||||||
Dimension(WxDxH)mm | 150x247x144 | 150x247x200 | 150x285x260 | 175x360x305 | 220x485x430 | 330x370x612 | 530x400x732 | ||
Net Weight(kg) | 4.3 | 4.8 | 8.2 | 9.5 | 15.2 | 31 | 53 | 59 | 91 |
Packing(WxDxH)mm | 235x360x235 | 235x360x290 | 230x395x350 | 278x470x415 | 280x555x495 | 430x500x690 | 635x500x830 | ||
Gross Weight(kg) | 4.8 | 5.3 | 8.8 | 10.1 | 15.9 | 32 | 56 | 61.3 | 94.5 |
MODEL | ZTY Three Phase | |||||
VA Rating | 3KVA | 6KVA | 10KVA | 15KVA | 20KVA | 30KVA |
INPUT | ||||||
Phase | Three Phase+N+GND | |||||
Voltage Range | Line Voltage 277Vac-433Vac | |||||
OUTPUT | ||||||
Voltage | 380V | |||||
Voltage Precision | ≤±3% | |||||
Frequency | 50/60Hz | |||||
Over-Voltage Protection | Output Voltage 250V±5V | |||||
Low-Voltage Protection | Output Voltage 183V±5V | |||||
Efficiency | ≥96% | |||||
OTHERS | ||||||
Display Model | LED / METER | |||||
Input/Output Device | Terminal | |||||
Waveform Distortion | No Affixation Waveform Distortion | |||||
Response Time | (±10% Varies) <1s | |||||
Insulation Resistance | ≥2MΩ | |||||
Anti-Electricy Intension | Low Frequency Sine Voltage 1500V Take 1 minute No Rout and Camber phenomena | |||||
Ambient Temperature | 0℃-40℃ | |||||
Relative Humidity | ≤95% | |||||
Working | Continue | |||||
Dimension(WxDxH)mm | 200x480x395 | 330x350x702 | 330x380x752 | 530x400x732 | ||
Net Weight(kg) | 14.5 | 35 | 37 | 51 | 58 | 95 |
Packing(WxDxH)mm | 260x555x505 | 460x435x790 | 555x420x840 | 635x500x830 | ||
Gross Weight(kg) | 16.8 | 37.6 | 40 | 54.2 | 61.6 | 105 |
· Q. What is an UPS and What it is for ?
An uninterruptible power supply (UPS) is a device that allows your computer or telephone switch or critical equipement to keep running for at least a short time or longer time when the primary power source is lost. It also provides protection from power surges, spikes, brownouts, interference and other unwanted problems on the supported equipment.
· Q. How long the UPS to run when power goes?
This can take 3 paths.
1.You can pick a UPS that is rated for pretty much the full VA you need so it will be running at 100% of capability and will thus last 'n' minutes.
2.You can pick a UPS that is rated at a much higher VA value than you really need so, for example, is running at 50% of capability and will thus last for longer than the UPS from option 1.
3.You can use extra external battery packs to run for longer. If charging capability allows, the more and the bigger batteries you take with, the longer time UPS runs.
or using a generator after about 6 hours, it will be more cost-effective, with a short runtime UPS to bridge the generator start-up gap.