Circulation Soft Water Cooling System ( air-water cooler)

 

Mode GPKL-II circulation soft water cooling system adopts closed cooling tower structure. Cooling soft water is flow in sealed water tank and cooling pipes. The inner circulation soft water is cooled by overhead fan and water-spray method using the principle absorbing heat when evaporation. The spray water circulate inside and closed cooling tower`s heat dissipation pipe, spray-water spray at pipes` surface through spray system, some heat is taken by dissipation and soft water temperature inside the pipe go down accordingly. The cut board stops water in hot air and un-evaporated water, make them flow through PVC heat exchange layer, the water in the layer is down by air, then temperature goes sown and fall down to the bottom of the tower.

Apply range: 60 kW –1200 kW induction heating power supply.

 

Features:

 

 

 

Service


 

Design as customer's specific demand

Onsite supporting engineer team

Technical consult and guiding

 

Using environment for H.F. welder
1. Environment requirements

1.1 Indoor installation, heating equipment and heating furnace should earthing well, earthing wire color must be obviously different form control wires, its section area >4mm2, earthing resistance should be no more than 4Ω.

1.2 Height above sea level should be no more than 1000 meters, or else reduce rated value for using.

1.3 Surroundings temperature: 5~40℃.

1.4 Air relative humidity should be no more than 85%.

1.5 No severe vibration, no conductive dust, no various causticity gas and explosion gas.

1.6 Installation gradient should be less than 5°.

1.7  Installed on excellent ventilation situations.

 

2.  Power net requirements

2.1 Power net voltage is sine wave, harmonics distortion should be no more than 5%.

2.2 Imbalance degree between 3-phase voltage should be less than ±5%.

2.3 Power net input voltage is line voltage AC 380V, the constant fluctuation range should be less than ±10%, 2.4 power net frequency variation should be no more than ±2% (i.e. between 49 ~ 51Hz).