PVC jacket compound for UL stardard wires and cables

Loading Port:Shanghai

Payment Terms:TT OR LC

Min Order Qty:-

Supply Capability:3000 Tons kg/month

Product Description:

PVC jacket compound for ULstandard wires and cables

I.                  Type andapplication

Type

Product

Application and Cable Specification

5621N

PVC jacket compound for UL standard at 60

Used for wires and cables which according with UL standard, such  as UL62, 83, 758, 1581 and etc.

5821N

PVC jacket compound for UL standard at 80

Used for wires and cables which according with UL standard, such  as UL62, 83, 758, 1581 and etc.

5921N

PVC jacket compound for UL standard at 90

Used for wires and cables which according with UL standard, such  as UL62, 83, 758, 1581 and etc.

5521N

PVC jacket compound for UL standard at 105

Used for wires and cables which according with UL standard, such  as UL62, 83, 758, 1581 and etc.

II.               Product description

PVC jacket compound for UL standard wires and cables, based on PVCresin, is made into granula by mixing, plastification and granulation withadding plasticizer, stabilizing agent, flame retardant and etc. The productsmeet various special requirements, such as different hardness, UV stable,environment friend (RoHs, REACH, PAHs, chlorinated alkanes free,  phthalate free, and etc.), sub-shine and fogsurface, low temperature resistant, PS/ABS transfer proof, rodent-repellent,termite-repellent, and transparent, and etc.

III.            Processing:

It is recommended that compound should be processed with commonextruder having a minimum L/D ratio of 20.

The following temperature() profileof extruder is recommended:

Zone

Zone 1

Zone 2

Zone 3

Zone 4

Head

Die

Temperature

140

160

170

175

175

175

IV.             Storageand transport

Packaging25kg/bag PE membrane inside bag and Kraft outsidebag.

Storage and transport: Avoiding in direct sunlight and weathering.The storage place should be in clean, cool, dry, and ventilated conditions.

V.                Properties

Table

Item

Unit

Standard Value

5621N

5821N

5921N

5521N

Tensile  Strength

 MPa

15.0

15.0

15.0

15.0

Elongation at Break

  %

150

150

150

150

Impact Brittleness Temperature

 

-20

-20

-20

-20

Volume  Resistivity, at 20

Ωm

1.0×109

1.0×109

1.0×109

1.0×109

Dielectric Strength

MV/m

18

18

18

18

Hot Deformation

  %

50

50

50

50

Thermal Stability Time

at 200

 min

60

80

100

120

Thermal Aging (UL oven)

Aging Temperature

100±1

100±1

121±1

136±1

Aging Time

h

168

240

168

168

Retention on Tensile Strength

  %

+85

+70

+85

+85

Variation on Elongation at Break

  %

+65

+65

+65

+65