PVC insulating compound for UL standard wires and cables

Loading Port:Shanghai

Payment Terms:TT OR LC

Min Order Qty:-

Supply Capability:3000 Tons kg/month

Product Description:

PVC insulating compound for UL standard wires and cables

I.                  Type andapplication

Type

Product

Application  and Cable Specification

5601N

PVC insulating compound for UL standard at  60℃

Used for wires and cables which according  with UL standard, such as UL62, 83, 758, 1581 and etc

5801N

No lead PVC insulating compound for UL  standard at 80℃

Used for wires and cables which according  with UL standard, such as UL62, 83, 758, 1581 and etc

5901N

No lead PVC insulating compound for UL  standard at 90℃

Used for wires and cables which according  with UL standard, such as UL62, 83, 758, 1581 and etc

5501N

No lead PVC insulating compound for UL  standard at 105℃

Used for wires and cables which according  with UL standard, such as UL62, 83, 758, 1581 and etc

II.               Productdescription

PVC insulatingcompound for UL standard wires and cables, based on PVC resin, is made intogranula by mixing, plastification and granulation with adding plasticizer,stabilizing agent, flame retardant and etc. The products meet various specialrequirements, such as different hardness, UV stable, environment friend (RoHs,REACH, PAHs, chlorinated alkanes free, phthalate free, and etc.), sub-shine and fog surface, low temperatureresistant, PS/ABS transfer proof, rodent-repellent, termite-repellent, andtransparent, and etc.

III.            Processing

It is recommended that compound should beprocessed with common extruder having a minimum L/D ratio of 20.

The following temperature(℃)profile of extruder is recommended:

Zone

Zone 1

Zone 2

Zone 3

Zone 4

Head

Die

Temperature  ℃

140

160

170

175

180

175

IV.             Storageand transport

Packaging:25kg/bag, PE membrane inside bag and Kraft outsidebag.

Storage and transport: Avoiding in directsunlight and weathering. The storage place should be in clean, cool, dry, andventilated conditions.

V.                 Properties

Table

Item

Unit

Standard  Value

5601N

5801N

5901N

5501N

Tensile Strength

≥MPa

15.0

15.0

15.0

15.0

Elongation at  Break

≥  %

150

150

150

150

Impact Brittleness Temperature

-15

-15

-15

-15

Volume Resistivity,  at 20℃

≥Ω﹒m

1.0×1011

1.0×1011

1.0×1011

1.0×1011

Volume Resistance at  working temperature

≥Ω﹒m

1.0×108

1.0×108

1.0×108

1.0×108

Dielectric Strength

≥MV/m

20

20

20

20

Hot Deformation

≤  %

40

40

30

30

Thermal Stability  Time at 200℃

≥min

60

80

100

120

Thermal Aging (UL  oven)

Aging Temperature

100±1

100±1

(113±1

121±1

136±1

Aging Time

h

168

240

(168

168

168

Retention on Tensile Strength

≥  %

+85

+85

+85

+85

Variation on Elongation at Break

≥  %

+65

+65

+65

+65